2.SYSTEM OVERVIEW
Engineering Data book
8
2
2-3. Outdoor Unit
Single Phase model
3 Phase model
2-4. Hot Water Cylinder
Outdoor unit
HWS-803H-E
HWS-1103H-E
HWS-1403H-E
Power supply
220-230V ~ 50Hz
Type
INVERTER
Function
Heating & Cooling
Heating
Capacity
(kW)
8.0
11.2
14.0
Input
(kW)
1.82
2.35
3.11
COP
(W/W)
4.40
4.77
4.50
Cooling
Capacity
(kW)
6.0
10.0
11.0
Input
(kW)
2.13
3.52
4.08
EER
(W/W)
2.82
2.84
2.70
Refrigerant
R410A
Dimension
HxWxD
(mm)
890x900x320
1,340x900x320
Outdoor unit
with bottom plate heater
HWS-
1103H8-E
HWS-
1403H8-E
HWS-
1603H8-E
HWS-
1103H8R-E
HWS-
1403H8R-E
HWS-
1603H8R-E
Power supply
380-400V 3N~ 50Hz
Type
INVERTER
Function
Heating & Cooling
Heating
Capacity
(kW)
11.2
14.0
16.0
11.2
14.0
16.0
Input
(kW)
2.39
3.21
3.72
2.39
3.21
3.72
COP
4.69
4.36
4.30
4.69
4.36
4.30
Cooling
Capacity
(kW)
10.0
11.0
13.0
10.0
11.0
13.0
Input
(kW)
3.52
4.08
4.80
3.52
4.08
4.80
EER
2.84
2.70
2.71
2.84
2.70
2.71
Refrigerant
R410A
Dimension
HxWxD
(mm)
1,340x900x320
Bottom plate heater
(W)
–
75
Hot water cylinder (option)
HWS-1501CSHM3-E
HWS-1501CSHM3-UK
HWS-2101CSHM3-E
HWS-2101CSHM3-UK
HWS-3001CSHM3-E
HWS-3001CSHM3-UK
Water volume
litres
150
210
300
Max water temperature
(°C)
75
Electric heater
(kW)
2.75 (230 V ~)
Height
(mm)
1,090
1,474
2,040
Diameter
(mm)
550
Material
Stainless steel
Summary of Contents for ESTIA HWS-1501CSHM3-E
Page 3: ...2 1 INTRODUCTION ...
Page 7: ...6 2 SYSTEM OVERVIEW ...
Page 11: ...10 3 SYSTEM SPECIFICATION ...
Page 60: ...59 5 OUTDOOR UNIT ...
Page 79: ...78 6 HOT WATER CYLINDER ...
Page 85: ...84 7 HYDRO UNIT INSTALLATION MANUAL ...
Page 132: ... 131 7 HYDRO UNIT INSTALLATION MANUAL Engineering Data Book MEMO ...
Page 133: ...132 8 OUTDOOR UNIT INSTALLATION MANUAL ...
Page 162: ... 161 8 OUTDOOR UNIT INSTALLATION MANUAL Engineering Data book MEMO ...
Page 163: ...162 9 OWNER S MANUAL ...
Page 179: ...Air to Water Heat Pump Engineering Data Book Oct 2010 ...