4.HYDRO UNIT
Engineering Data book
50
4
Cooling capacity and power input
* Cooling capacity and power input are the data at rated compressor operating frequency of rated condition 1
* Power input does not include water pump power.
* Cooling capacity and power input are measured in accordance with EN14511.
Capacity (kW)
LWT (°C)
7
10
13
15
18
TO
(°C)
20
11.10
12.13
13.15
13.85
14.89
27
11.64
12.72
13.79
14.52
15.61
30
11.22
12.26
13.29
13.99
15.05
35
10.49
11.46
12.43
13.09
14.07
40
9.83
10.74
11.65
12.14
12.93
43
9.44
10.31
11.19
11.58
12.24
Power input (kW)
LWT (°C)
7
10
13
15
18
TO
(°C)
20
2.39
2.43
2.48
2.51
2.55
27
3.11
3.17
3.24
3.27
3.32
30
3.26
3.33
3.39
3.43
3.48
35
3.50
3.57
3.64
3.68
3.74
40
3.88
3.96
4.03
4.04
4.08
43
4.11
4.19
4.27
4.27
4.29
COP
LWT (°C)
7
10
13
15
18
TO
(°C)
20
4.65
4.98
5.30
5.52
5.85
27
3.74
4.01
4.26
4.44
4.70
30
3.44
3.68
3.92
4.08
4.32
35
3.00
3.21
3.42
3.56
3.77
40
2.53
2.72
2.89
3.00
3.17
43
2.30
2.46
2.62
2.71
2.86
TO
:
Outdoor temperature (DB°C)
LWT
:
Leaving water temperature (°C)
Summary of Contents for ESTIA HWS-1501CSHM3-E
Page 3: ...2 1 INTRODUCTION ...
Page 7: ...6 2 SYSTEM OVERVIEW ...
Page 11: ...10 3 SYSTEM SPECIFICATION ...
Page 60: ...59 5 OUTDOOR UNIT ...
Page 79: ...78 6 HOT WATER CYLINDER ...
Page 85: ...84 7 HYDRO UNIT INSTALLATION MANUAL ...
Page 132: ... 131 7 HYDRO UNIT INSTALLATION MANUAL Engineering Data Book MEMO ...
Page 133: ...132 8 OUTDOOR UNIT INSTALLATION MANUAL ...
Page 162: ... 161 8 OUTDOOR UNIT INSTALLATION MANUAL Engineering Data book MEMO ...
Page 163: ...162 9 OWNER S MANUAL ...
Page 179: ...Air to Water Heat Pump Engineering Data Book Oct 2010 ...