5.OUTDOOR UNIT
Engineering Data book
60
5
5-1. Specification
5-1-1. Outdoor unit specifications
Outdoor unit
HWS-803H-E
HWS-1103H-E
HWS-1403H-E
Power supply
1 ~ 220-230V 50Hz
Compressor
Type
Twin rotary type with DC-Inverter variable speed control
Motor Output
kW
2.0
3.75
Pole
4
Refrigerant charged
1.8
2.7
Refrigerant control
Pulse motor valve
Pipe length
Minimum
m
5
Maximum
m
30
Height difference
Outdoor-Hydro unit
m
30
Appearance
Color
Silky shade (Muncel 1Y8.5-0.5)
Material
PCM
Outer dimension
Height
mm
890
1340
Width
mm
900
900
Depth
mm
320
320
Unit weight
kg
63
93
Packing
dimension
Height
mm
975
1425
Width
mm
971
971
Depth
mm
436
436
Total weight
unit and packing
kg
69
100
Heat exchanger
Type
Finned tube
Fan unit
Fan
Propeller fan
Standard air flow
m
3
/min
57
101
103
Motor
W
63
100+100
Bottom plate heater
W
–
–
–
Sound pressure
level
Heating normal
dBA
49
49
51
Heating low noise*
dBA
42
44
44
Cooling normal
dBA
47
50
51
Cooling low noise*
dBA
44
45
45
Hot water normal
dBA
49
49
51
Hot water low noise
dBA
42
44
44
Operation
outdoor temp
Heating
°C
-20 to 25
Cooling
°C
10 to 43
Hot water
°C
-20 to 43
Refrigerant pipe
Gas
mm
15.9
Liquid
mm
9.5
Summary of Contents for ESTIA HWS-1501CSHM3-E
Page 3: ...2 1 INTRODUCTION ...
Page 7: ...6 2 SYSTEM OVERVIEW ...
Page 11: ...10 3 SYSTEM SPECIFICATION ...
Page 60: ...59 5 OUTDOOR UNIT ...
Page 79: ...78 6 HOT WATER CYLINDER ...
Page 85: ...84 7 HYDRO UNIT INSTALLATION MANUAL ...
Page 132: ... 131 7 HYDRO UNIT INSTALLATION MANUAL Engineering Data Book MEMO ...
Page 133: ...132 8 OUTDOOR UNIT INSTALLATION MANUAL ...
Page 162: ... 161 8 OUTDOOR UNIT INSTALLATION MANUAL Engineering Data book MEMO ...
Page 163: ...162 9 OWNER S MANUAL ...
Page 179: ...Air to Water Heat Pump Engineering Data Book Oct 2010 ...