7.CHECKING THE EQUIPMENT STATUS WITH TopAccess
Error Codes 99
7 CHECKING THE EQUIPMENT STATUS WITH TopAccess
2C14
Invalid parameter specified
If you are using a template, create it again. If
the error still persists, turn the power OFF
and then back ON, and then try again.
2C15
Mail size exceeded limit or maximum size
You are sending too many documents at a
time. Send them separately.
2C30-2C33
Disk access error
Complete any running jobs first before
reperforming the job in error. If the error still
persists, turn the power OFF and then back
ON, and then try again.
2C40
Failed to convert image file format
This error occurs when conversion to a
highly compressed PDF format fails. Do the
scanning again. If the error still persists, Use
the normal PDF format. When this error
occurs in conversion other than to a highly
compressed PDF format, turn the power
OFF and then back ON. Then try to scan
again. If the error still persists, contact your
service representative.
2C43
Encryption error. Failure to create a file
If the error still persists after reattempting,
turn the power OFF and then back ON. Then
make another effort.
2C44
Creating a file was not allowed
Creating an unencrypted file was not
allowed. Configure the encryption settings
and try again. To create an unencrypted file,
consult the administrator.
2C45
Failure in making meta data
Make sure that the template setting is
correct, and do the scanning again. If the
error still persists, turn the power OFF and
then back ON, and then try again.
2C60
HDD full failure during processing
Reduce the number of pages of the problem
job and try again. Check whether the server
or local disk has sufficient space in its
capacity.
2C61
Failure to read Address Book
Turn the power OFF and then back ON. Try
the problem job again. Reset the data in the
Address Book and reattempt it. If the error
still persists, contact your service
representative.
2C63
Terminal IP address unset
Ask your administrator to set the IP address
of the equipment.
2C64
Terminal mail address unset
Ask your administrator to set the Email
address of the equipment.
2C65, 2C66,
2C69
Failure to connect to SMTP server
Make sure that the SMTP server is correctly
working or the SMTP server address has
been set correctly.
2C6A
Failure to send Email message
Turn the power OFF and then back ON. Try
scanning again. If the error still persists,
contact your service representative.
Error Code
Problem Description
Corrective Action
Summary of Contents for E-Studio 557
Page 1: ...MULTIFUNCTIONAL DIGITAL SYSTEMS Troubleshooting Guide ...
Page 8: ...6 CONTENTS ...
Page 58: ......
Page 68: ......
Page 90: ......
Page 108: ......
Page 114: ...112 INDEX ...