9. CHECK POINTS AFTER REPAIRING
9-1. Warning and Caution After Repairing
x
After the end of working, measure insulation resistance between the charging part
(power cord plug) and the non-charging metallic part (ground) with an insulation
resistance meter (500 V) and check the resistance is 10 M
Ω
or more.
Failing to check the insulation resistance cause
a short circuit, an electric shock
or other
diseases to the customer.
x
Use an exclusive 110 VAC/15 A socket for the washing machine.
x
Use an exclusive 220 VAC/17 A socket for the washing machine. (Except above models)
Otherwise,
an electric shock
or
ignition
may cause. Sharing the same socket with other
instrument causes heating of a branch socket and result in
a fire.
x
Connect the grounding wire.
Failing to do so may cause
an electric shock
when a short circuit occurs.
Consult an electric work shop or a sales shop.
x
Do not install in a bath room or a place exposed to wind or rain.
An electric shock
or
a short circuit
may cause
a fire.
x
Wipe off the dust adhered to the plug of the power cord
.
Dust may cause
a fire.
CHECK INSULA-
TION RESISTANCE
USE EXCLUSIVE
SOCKET
CONNECT
GROUNDING WIRE
WARNING
DO NOT USE
WET PLACE
REMOVE DUST
x
Before starting washing, open the faucet and check that the water supply hose joint is
not loose and no water leaks.
The loose screw or hose joint may cause water leakage resulting in an unexpected
damage.
WATER LEAKAGE
CAUTION
Summary of Contents for AW-9500SBJ/SBK/SBX
Page 41: ... 40 10 2 Top Cover Assembly TAPPING SCREW M4 x 16S ...
Page 43: ... 42 10 3 Panel Assembly TRUSS HEAD TAPPING SCREW M4 x 16S TRUSS HEAD TAPPING SCREW M4 x 16S ...
Page 45: ... 44 10 4 Body Assembly BIND TAPPING SCREW M5 x 20S BIND TAPPING SCREW M5 x 20S ...
Page 49: ... 48 10 6 Motor and Packaging Assembly ...
Page 51: ... 50 ...