13.4 - Space and obstacles
For installation, adapt the spaces to allow easy access to the persons involved in processing and
maintenance operations. In addition, before installation, make sure that enough space is available
for the necessary manoeuvres. The installation area must be free of obstacles. Also consider
adequate aeration around the machine.
13.5 - Electrical installation
The electric system meets the
Declaration of Conformity attached to the instructions for use
and
it has been manufactured according to CEI Standards, Law 186/68 and Law 46/90.
The standard motors meet DIN/ISO Std. IP 54.
This operation must be carried out by specialised and qualified personnel. All the operations
described in this paragraph must be carried out with the current switched off.
The panel, according to standards, is fitted with self-locking line circuit breaker.
TEM will not consider itself liable for any damages or accidents caused by mistakes in installing
electrical equipment of other design or manufacture than those supplied by TEM.
-
Connect the plug provided with the machine to a suitable socket and check (if three-phase)
that the motor/s turn/s in the correct direction of rotation. If necessary, invert the phases
making reference to the wiring diagrams given in the chapters that follow and allow the
work to be carried out only by skilled personnel or trained by TEM.
Please remember that the electric system of the user must meet Std. CEI 64.8 (CENELEC HD 384,
IEC 364). The terminal strip must be connected to the user system taking account of the maximum
input and the following requirements must be foreseen:
-
Equi-potential earth system .
-
Automatic protection devices co-ordinated with the equi-potential system in such a way as
to guarantee automatic breaking (30 mA magneto-thermal differential device).
Figure 18 – Electric installation
ATTENTION:
ALWAYS REFER TO THE ELECTRIC DIAGRAM CONTAINED
INSIDE THE ELECTRIC BOARD