Voltage Fault Protection
If the AC voltage supplied to the AVR ELITE is too high or too low voltage (see reference chart at the end
of this section) for 1 second or more, a voltage fault message is displayed and the back panel fault
output is turned on. The unit automatically goes into shut down mode so the voltage to each power
output is automatically turned off even while the mains power to the unit remains in the ON position.
The front panel display will alternate to show either of the following message pairs:
OR
When the AC supply voltage has returned to a normal operating range for 1 minute consecutively the
AVR ELITE will resume normal operation and the High or Low AC Voltage advisory message will no longer
appear on the LCD display. The output zones will provide power again and be turned on in sequential
order with the delay between zones as defined in System Setup.
Nominal
Input
Output Fully
Regulated
Output
Range
Auto
Shutdown
Low Input
Voltage
Auto
Shutdown
High
Input
Voltage
Output
Range
Before
Auto
Shutdown
Fully
Regulated
Input
Range
Auto
Turn
On
Low
Input
Value
Auto
Turn
On
High
Input
Value
North American
120
120
+/- 4V
116-124
<85
>135
110-130
90-130
90
130
240
120
+/- 4V
116-124
<170
>270
110-130
180-260
180
260
International
220
220
+/- 8V
212-228
<150
>250
200-240
160-240
160
240
230
230
+/- 8V
222-238
<160
>260
210-250
170-250
170
250
240
240
+/- 8V
232-248
<170
>270
220-260
180-260
180
260