Thermal Fan Switch (Workman HDX and HDX--D)
The thermal fan switch is threaded into the thermostat
housing on the engine (Fig. 32). The fan switch is a nor-
mally open switch that closes when the engine coolant
temperature reaches approximately 198
o
F (92
o
C).
There is a green wire attached to the switch. When the
thermal fan switch closes, the radiator fan is energized.
Testing
1. Park machine on a level surface, raise bed, stop en-
gine, apply parking brake and remove key from ignition
switch.
2. Install bed support on bed lift cylinder to prevent bed
from lowering.
CAUTION
Make sure engine is cool before removing the
thermal fan switch.
3. Lower the coolant level in the engine, remove wire
harness connector from thermal fan switch and remove
the switch from the engine.
4. Put fan switch in a container of oil with a thermometer
and slowly heat the oil (Fig. 33).
CAUTION
Handle the hot oil with extreme care to prevent
personal injury or fire.
NOTE:
Prior to taking resistance readings with a digital
multimeter, short the meter test leads together. The me-
ter will display a small resistance value (usually 0.5
ohms or less). This resistance is due to the internal resis-
tance of the meter and test leads. Subtract this value
from from the measured value of the component you are
testing.
5. Check continuity of the switch with a multimeter
(ohms setting). The thermal fan switch is normally open
and should close at approximately 198
o
F (92
o
C). As the
switch cools, it should open at approximately 180
o
F
(82
o
C).
6. Replace thermal fan switch if necessary.
7. Install fan switch to the water pump.
A. Clean threads of water pump housing and switch
thoroughly. Apply thread sealant to the threads of the
switch.
B. Install switch into the water pump housing and
tighten. Torque from
16 to 20 ft--lb (22 to 27 N--m)
.
C. Connect green wire harness wire to switch.
8. Fill engine cooling system.
9. Remove bed support from lift cylinder and lower bed.
1. Thermostat housing
2. Thermal fan switch
3. Temp sender
Figure 32
1
2
3
Figure 33
Electrical System
Summary of Contents for Workman HD Series
Page 2: ...Workman HD Series This page is intentionally blank ...
Page 4: ...Workman HD Series This page is intentionally blank ...
Page 6: ...Workman HD Series This page is intentionally blank ...
Page 46: ...Rev A Workman HDX Page 3 28 Briggs Daihatsu Gasoline Engine This page is intentionally blank ...
Page 68: ...Workman HD Page 5 4 Kohler Gasoline Engine This page is intentionally blank ...
Page 95: ...Workman HD Series Page 6 19 Drive Train This page is intentionally blank Drive Train ...
Page 140: ...Workman HD Series Page 6 64 Drive Train This page is intentionally blank ...
Page 155: ...Workman HD Series Page 7 15 Chassis This page is intentionally blank Chassis ...
Page 159: ...Workman HD Series Page 7 19 Chassis This page is intentionally blank Chassis ...
Page 167: ...Workman HD Series Page 7 27 Chassis This page is intentionally blank Chassis ...
Page 216: ...Workman HD Series Page 9 2 Hydraulic System This page is intentionally blank ...
Page 244: ...Workman HD Series Page 9 30 Hydraulic System This page is intentionally blank ...
Page 274: ...Workman HD Series Page 9 60 Hydraulic System This page is intentionally blank ...
Page 296: ...Rev A Workman HDX HDX D Page 10 22 Front Wheel Drive 4WD This page is intentionally blank ...
Page 298: ...Workman HD Series Electrical Drawings Page 11 2 This page is intentionally blank ...
Page 309: ...Page 11 13 This page is intentionally blank ...
Page 310: ...Page 11 14 Front Wire Harness Drawing Workman HD Series All Models 3RD HIGH LOCKOUT SWITCH ...
Page 318: ......