FLOW REGULATOR:

Determines the rate at which

the material flows from the hopper. The highest number
setting (7) on the regulator scale indicates the largest
opening, for maximum flow of material. The lowest
number setting (1) indicates the smallest opening, for a
minimum flow of material.  At (0) the disc is closed.
Note the stop pin which is chained to the flow regulator:

a.

If the spreader is not equipped with the flow control
kit, the stop pin is used to stop the flow regulator
handle in the setting of the desired rate of material
flow.

b. 

If the spreader is equipped with the flow control kit,
the stop pin is NOT USED. The rate of material
flow is controlled by the limit switches.

IF THE SPREADER IS NOT EQUIPPED WITH THE
FLOW CONTROL KIT, THE FLOW CONTROL HAN-
DLE SHOWN IN FIG. 3 IS USED AS DESCRIBED
BELOW.

Fig. 3

1. 

Flow Control Handle 

2. 

Flow Regulator

FLOW CONTROL HANDLE:

Opens and closes the

regulator disc in the hopper opening to start or stop the
flow of material.  Pull the handle forward (toward the
operator) to open the regulator disc.  Push the handle
back (away from the operator) to close the regulator
disc.

IF THE SPREADER IS EQUIPPED WITH THE FLOW

CONTROL KIT, THE FLOW OF MATERIAL IS CON-
TROLLED BY THE ELECTRIC CONTROL SWITCH
INCLUDED WITH THAT KIT.

ELECTRIC CONTROL SWITCH:

Opens and closes

the regulator disc in the hopper opening, to start or stop
the flow of material. Position the toggle switch at the
“OPEN” or “CLOSE” position as indicated by the decal
on the control box. See Fig. 4.

Fig. 4

1.

Electric control switch

SPOUT ARC SETTING:

The embossed plus “+” and minus “–” signs on the

3

ROTATING MEMBERS CAN CAUSE 

SERIOUS INJURY!

Before making any adjustments or repairs on the
spreader:

• Stop 

the 

Workman

®

vehicle and set the

parking brake.

• 

Shut off the Workman

®

's engine and remove

the key from the ignition.

• 

Disengage all power and wait until all mov-
ing parts have stopped.

DANGER

Summary of Contents for PA-17

Page 1: ...safety instructions that follow IMPORTANT identifies special mechanical information and NOTE identifies general information worthy of special attention These instructions are provided as a guide for t...

Page 2: ...ny shields removed during ser vicing or adjustments 9 To be sure of optimum performance and safety always purchase genuine TORO replacement parts and accessories Replacement parts and accessories made...

Page 3: ...w Regulator FLOW CONTROL HANDLE Opens and closes the regulator disc in the hopper opening to start or stop the flow of material Pull the handle forward toward the operator to open the regulator disc P...

Page 4: ...rc settings for a variety of materials MATERIAL SPREAD WIDTH SPOUT ARC Granulated 40 ft 12m Min Prilled 40 ft 12m Max Powdered 20 ft 6m Midway Urea 32 ft 10m Max The spreader unit can be fitted with t...

Page 5: ...0 5 6 8 0 9 7 12 1 39 5 26 4 19 3 15 6 12 8 180 1 119 8 89 5 71 9 59 1 451 9 300 7 201 1 180 9 154 9 804 3 536 0 402 0 322 0 267 4 1232 3 819 9 616 0 491 2 410 4 1639 8 1092 9 819 9 654 8 546 1 1999 5...

Page 6: ...the application rate required 2 Close the regulator disc using the toggle switch on the control box or the flow control handle 3 Take the machine to the work site 4 Just prior to the actual spreading...

Page 7: ...slowly while spraying water inside the hopper 3 Open the regulator disc and spray the agitator and regulating plate 4 Spray all of the outside surfaces of the spreader MAINTENANCE AFTER THE INITIAL RU...

Page 8: ......

Reviews: