Page 1: ...P345MTR and P345KPMTR Multi Technology Installation Manual 125 KHz and 13 56 MHz Readers DN1870 0905 ...

Page 2: ...i P345MTR and P345KPMTR Readers Installation Manual Table of Contents Introduction 5 Features 6 Mounting 6 Installation Considerations 8 Wiring 9 Installation Notes 10 Troubleshooting 11 Technical Specifications 12 ...

Page 3: ...TR P345KPMTR and other Kantech products contact technical support Monday to Friday See the following table for the technical support phone numbers Country Region Phone Numbers Support Hours Email North America Toll Free 888 222 1560 GMT 05 00 US and Canada Direct 450 444 2030 Fax 450 444 2029 8 00 to 20 00 kantechsupport tycoint com Latin America GMT 03 00 Argentina Direct 5411 4717 2929 5411 4717...

Page 4: ...nts of the Canadian Interference Causing Equipment Regulations The P345MTR and P345KPMTR readers are also compliant with EN55022 1998 amendment 1 1995 Class A Europe Toll Free 800 CALL TYCO 800 2255 8926 GMT 01 00 Bahrain 800 04127 8 00 to 18 00 tfsemea support tycoint com France 33 04 72 79 14 83 Greece 00 800 31 22 94 53 Russia 8 10 800 2052 1031 Spain 900 10 19 45 Turkey 00 800 31 92 30 37 Unit...

Page 5: ...s indicated in the control unit s installation instructions For this product the HID KSF Kantech Secure Format and ioProx Kantech XSF have not been evaluated by UL UL has not evaluated the RS 485 Output of this reader Tamper Circuit Electrical Rating for UL Installations Pins 11 12 is 100 mA at 30 VDC CE Compliance EN50364 Limitation of human exposure to electromagnetic fields from devices operati...

Page 6: ... 3 Electromagnetic Compatibility and Radio Spectrum Matters ERM ElectroMagnetic Compatibility EMC Standard for Radio Equipment and Services Part 3 Specific Conditions for Short Range Devices SRD Operating on Frequencies between 9 KHz and 40 GHz RoHS Restriction on Hazardous Substances This standard restricts the use of the following substances Lead cadmium mercury chromium IV polybrominated biphen...

Page 7: ...d CE Clear Entry The reader outputs the PIN code in the 8 bit burst Wiegand It also has the ability to read and verify the PIN on a Smart Card This feature is enabled with the use of program cards Please contact Kantech for more information on the PIN on Card function Table 1 Compatible Credential Formats ioProx Kantech XSF CASI RUSCO Prox Lite HID KSF Kantech Secure Format ISO 14443A MIFARE Secto...

Page 8: ...eed transient voltage suppressor diodes IP65 rated sealed electronics for deployment in both interior and exterior environments Integrated reader tamper protection Mounting Mount the single gang backplate with tamper magnet installed onto the wall Figure 1 P345MTR Reader Backplate with Tamper Switch Magnet Note Mounting holes fit standard U S single width electrical box and standard European EMEA ...

Page 9: ...ation Manual Figure 2 Mounting Assembly with Isolation Spacer Optional Please note that Figure 2 shows the P345MTR reader and cover plate Although the P345KPMTR keypad reader and front cover plate differ the mounting assembly is the same as the P345MTR ...

Page 10: ...nter distance between two readers is greater than or equal to four 4 inches 101 6 mm Two readers can simultaneously read the same badge or tag if the distance between the two readers is less than 4 inches center to center If the distance between the two readers is less than four inches field interference between the two readers may result in a double badge read Note If two readers are being placed...

Page 11: ...he cable wires can potentially corrode and short together if not carefully mounted and tightly fastened in the connector body Table 3 Connector Pins Table 4 indicates maximum wiring distances per Wiegand standard with the three most common gauges of cable Table 4 Maximum Cable Distance per Wire Gauge Pin Description Pin Description 1 Buzzer 7 External Green LED Control 2 Ground 8 External Red LED ...

Page 12: ...ct the power supply from the controller to the reader The ground line of the local power supply must be connected to the power supply of the controller Figure 3 Wiring Examples to Kantech Controllers 2 The unit needs to be operated with a power source with limited power consumption according to EN 60950 1 2003 paragraph 2 5 3 Use of a pull up resistor may be required by some controllers others tha...

Page 13: ...onnected The door does not open and the green LED does not light when a qualified credential is presented Verify that the door strike and the green LED are wired correctly Verify that the access credential has been entered and that the reader has been properly configured in the host system The green LED does not light but the door strike unlocks the door when a valid credential is presented Verify...

Page 14: ...r SmartFrame in both 125 kHz and 13 56 MHz implementations HID Prox at 125 kHz All Formats HID KSF Kantech Secure Format ioProx Kantech XSF PIN Code Entry Keys Model P345KPMTR only Twelve PIN code entry keys 0 9 Command Enter and CE Clear Entry Standard Color Black Dimensions with backplate height width depth 4 37 x 3 31 x 1 10 in 11 09 x 8 41 x 2 79 cm Power Supply Rated Voltage 9 4 to 16 VDC 125...

Page 15: ...ure of each individual credential Standard Wiegand Output including ID Pass Through Option Serial Number Read Fixed Wiegand bit stream option SmartFrame encrypted MIFARE Sector read and conversion to Wiegand Consult your Kantech representative for available reconfiguration cards for your reader 8 bit burst Wiegand PIN code P345KPMTR only PIN on card featured P345KPMTR only Upgrade Future Use Compl...

Page 16: ...Copyright 2009 Tyco International Ltd and its Respective Companies All Rights Reserved www kantech com DN1870 0905 ...