Condition
Possible Cause
Correction
Machine aerates, but aeration
Low accumulator pre-charge or
Charge accumulator with dry Ni
hole depth is shallow or inconsis
damaged accumulator - TEST
trogen. Rebuild or replace accu
tent (continued).
NO. 1.
mulator if necessary.
Low water system pressure AND
Rebuild pump.
flow - TEST NO. 2.
Low water system pressure (flow is
NOTE: When testing, make sure
OK) - TEST NO. 2.
cam is not holding water valve
open - rotate gear so cam is off of
valve lifter.
If water is exiting relief valve out
let hose, replace relief valve. DO
NOT attempt to adjust.
Rebuild water valve.
Low water system flow (pressure is
Check engine speed and correct
OK) - TEST NO. 2.
if necessary.
Rebuild pump.
Improper water valve lift - TEST
Perform valve lift adjustment. Re-
NO. 3.
pair valve or replace cam if nec
essary.
Worn or damaged water valve -
Rebuild water valve.
TEST NO. 2.
Water in gear case
Worn or damaged water valve low
Rebuild water valve.
(milky or brown color in oil)
pressure water seal and oil seal.
Oil leaking from below gear case
Worn or damaged water valve oil
Rebuild water valve.
shim area.
seal.
Water in pump crankcase
Worn or damaged water pump low
Rebuild pump head and plunger
(milky or brown color in oil)
pressure seal or cracked ceramic
sleeves.
plunger.
Engine dies when water system
Low engine RPM.
Throttle must be in FAST posi
is engaged.
tion. Adjust carburetor fast setting
to 3450 to 3550 RPM - no load.
Relief pressure too high - TEST
Replace relief valve. DO NOT at-
NO. 2.
tempt to adjust.
Low engine power.
Check for contaminated fuel,
plugged fuel filter or fuel line,
plugged air cleaner, bad spark
plug. (see Chapter 3 - Engine).
Jammed or siezed pump or gear-
Inspect components and repair
case.
as necessary.
Hydroject 3010
Page 6 - 11
Troubleshooting
Summary of Contents for HydroJect 3010
Page 2: ...Hydroject 3010...
Page 4: ...Hydroject 3000 4000...
Page 10: ...Equivalents and Conversions Product Records and Maintenance Page 2 2 Hydroject 3010...
Page 44: ...Repairs Page 4 26 Hydroject 3010...
Page 72: ...Repairs Page 5 28 Hydroject 3010...
Page 102: ...This page is intentionally blank Repairs Page 6 28 HydroJect 3010...
Page 109: ...IRXU ORFDWLRQV 7RUTXH WR IW OE LJXUH GURMHFW 3DJH 5HSDLUV...
Page 118: ...This page is intentionally blank Electrical Diagrams Page 8 2 Hydroject 3010...
Page 119: ...Page 8 3 Electrical Schematic Hydroject 3010...
Page 120: ...Hydroject 3010 Main Harness Page 8 4...
Page 121: ...Page 8 5 Main Wiring Diagram Hydroject 3010...
Page 122: ...Hydroject 3010 Control Panel Harness Page 8 6...
Page 123: ...Hydroject 3010 Tiller Wire Harness and Diagram Page 8 7...
Page 124: ......