Aerate Operation Problems
Condition
Possible Cause
Correction
Machine continues to aerate (but
See Safety Interlock System Prob
should not) with traction bail in
lems.
neutral.
Machine aerates (but should not)
See Safety Interlock System Prob
with with machine raised in trans
lems.
port position.
Machine starts aerating (but
Water pressure switch faulty.
Test switch and replace if faulty.
should not) with inlet water pres
sure of less than 20 to 30 PSI, or
Water pressure switch wiring faulty.
Check for short in pressure
machine does not stop aerating if
switch/controller connections and
inlet water pressure drops to
wiring and repair as necessary.
10 PSI.
Controller faulty.
Replace controller.
Machine does not start aerating
Problem not electrical (see Chap
when engage button is pushed in
ter 6 - Water System.)
(pump drive belt does NOT ro
tate).
Loose or broken wire.
Check all connections and wiring
and repair as necessary.
Accumulator charge switch faulty.
Test switch and replace if faulty.
Accumulator high pressure switch
Accumulator high pressure
faulty.
switch faulty.T
Pressure gauge switch faulty.
Test switch and replace if faulty.
Pump clutch faulty.
Test clutch and replace if faulty.
Pump relay faulty.
Test relay and replace if faulty.
Aerator stop (disengage) switch
Test switch and replace if faulty.
faulty.
Wheel position switch faulty.
Make sure switch is installed
properly. Test switch and replace
if faulty.
Aerator start (engage) switch faulty.
Test switch and replace if faulty.
Controller faulty.
Replace controller.
Hydroject 3010
Page 5 - 11
Troubleshooting
Summary of Contents for HydroJect 3010
Page 2: ...Hydroject 3010...
Page 4: ...Hydroject 3000 4000...
Page 10: ...Equivalents and Conversions Product Records and Maintenance Page 2 2 Hydroject 3010...
Page 44: ...Repairs Page 4 26 Hydroject 3010...
Page 72: ...Repairs Page 5 28 Hydroject 3010...
Page 102: ...This page is intentionally blank Repairs Page 6 28 HydroJect 3010...
Page 109: ...IRXU ORFDWLRQV 7RUTXH WR IW OE LJXUH GURMHFW 3DJH 5HSDLUV...
Page 118: ...This page is intentionally blank Electrical Diagrams Page 8 2 Hydroject 3010...
Page 119: ...Page 8 3 Electrical Schematic Hydroject 3010...
Page 120: ...Hydroject 3010 Main Harness Page 8 4...
Page 121: ...Page 8 5 Main Wiring Diagram Hydroject 3010...
Page 122: ...Hydroject 3010 Control Panel Harness Page 8 6...
Page 123: ...Hydroject 3010 Tiller Wire Harness and Diagram Page 8 7...
Page 124: ......