HYDRAULIC DRIVE SYSTEM
6-26
36” & 40” Toro GrandStand Service Manual
6
3. Secure the reservoir tank to the tank bracket using
the two sets of bolts, washers and nuts (Fig. 514).
6. Fill the reservoir to the “COLD” fluid level with the
specified hydraulic fluid. See your Operator’s Manual
for the specified fluid (Fig. 517).
5. Secure the return hose to the return fitting using the
hose clamp (Fig. 516).
Fig. 514
DSCN-2890a
4. Install the suction hose to the suction fitting (Fig.
515).
Fig. 515
DSCN-2887a
Fig. 516
DSCN-2906a
Fig. 517
fig. 71 G012685
7. Purge the air from the hydraulic system. See
“Bleeding the Hydraulic System” on page 6-35.
A. Cap
C. Cold fluid level-full
B. Baffle
D. Hot fluid level-full