HYDRAULIC DRIVE SYSTEM
6-33
36” & 40” Toro GrandStand Service Manual
6
11. Cap the wheel motor fittings so debris does not enter
the system.
12. Attach the hydraulic hoses to the flow test gauge
(Fig. 538).
Note: When using a flow test gauge that is not bi
directional, damage to the flow tester could
occur if the machine is operated in reverse.
14. Run the machine for 2 minutes in forward (no load)
to purge air from the system.
15. Run the machine at full throttle (no load). Verify the
RPM with a tachometer: 3200
+ 150 RPMs. Do not
exceed 3600 RPM.
16. With the drive control fully forward, slowly tighten the
restriction valve until the gauge indicates 300 PSI
(21 bar) (Fig. 540).
Fig. 538
IMG-0916a
13. Open the restriction valve all the way (counter-
clockwise) (Fig. 539).
Fig. 539
IMG-0917a
Fig. 540
IMG-0921a
17. Record the flow reading from the bi-directional flow
meter. Make a second flow reading at 1100 PSI and
record that reading (Fig. 541).
Fig. 541
IMG-0920a
Summary of Contents for GrandStand 74534
Page 1: ...Toro 36 40 GrandStand Service Manual LCE Products ...
Page 3: ...ABOUT THIS MANUAL THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...TABLE OF CONTENTS vi 36 40 Toro GrandStand Service Manual THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 67: ...CHASSIS 3 48 36 40 Toro GrandStand Service Manual 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 111: ...CONTROLS 4 44 36 40 Toro GrandStand Service Manual 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 133: ...ENGINE 5 22 36 40 Toro GrandStand Service Manual 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 265: ...ELECTRICAL 8 44 36 40 Toro GrandStand Service Manual 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 268: ...Toro 36 40 GrandStand Service Manual Form Number 492 9236 ...