HYDRAULIC DRIVE SYSTEM
6-11
36” & 40” Toro GrandStand Service Manual
6
Pump Installation
22. Remove the two sets of bolts and nuts securing
the pump control arm to the pump RTN (Return to
Neutral) assembly (Fig. 460).
1. Transfer the high pressure hose identification marks
to the replacement pump.
2. Secure the pump control arm to the RTN (Return
to Neutral) assembly using the bolts and nuts (Fig.
461).
21. Loosen the jam nut securing the suction hose fitting,
then remove the fitting (Fig. 459).
Fig. 459
DSCN-3032a
Fig. 460
DSCN-3038a
Fig. 461
DSCN-3038a
23. To service the pump, refer to the HydroGear Pump
Service Manual (BLN-52503).
3. Install the suction hose fitting to the pump (Fig. 462).
Note: Do not tighten the jam nut at this time.
Fig. 462
DSCN-3032a