![Toro Air Cool Z Master 96in 74090 Software Manual Download Page 10](http://html1.mh-extra.com/html/toro/air-cool-z-master-96in-74090/air-cool-z-master-96in-74090_software-manual_1133466010.webp)
g038364
Figure 24
1.
Trip Statistics 1
4.
Displays US gallons/liters
of fuel
2.
Displays engine hours
5.
Play/Start
3.
Displays PTO hours
6.
Reset
When a trip statistic is playing, the statistics are not
highlighted and the reset button is blacked out and
not available. Pressing the pause button stops the
collection of data.
g038365
Figure 25
1.
Trip Statistics 4
4.
Displays US gallons/liters
of fuel
2.
Displays engine hours
5.
Pause/Stop
3.
Displays PTO hours
Press the toggle button on the Trip Statistics 5 screen
to go back to the main Trip Statistics screen.
Advanced Settings Menu
When the advanced settings menu is selected, the
module prompts you for a 4 digit passcode. The
default digits on the display screen are 0 0 0 0.
g030221
Figure 26
1.
Enter password
4.
Enter/Return
2.
Active digits
5.
Decrease
3.
Increase
The passcode is
1 9 8 2
. When the active digit is
highlighted, press the increase or decrease buttons to
scroll through digits from 0 to 9. Press enter to select
the highlighted digit.
If you enter the incorrect password, the module takes
you back to the menu select screen. When the correct
password is entered, you can scroll between the
following screens:
•
Hydraulic Transmission Oil (page 10)
•
Engine Oil (page 11)
•
Historical Error (page 11)
•
•
Engine Settings (page 12)
•
Calibrate Engine Settings (page 12)
•
Factory Defaults (page 13)
Hydraulic Transmission Oil
After performing the necessary maintenance, this
screen allows you to reset the number of hours until
the hydraulic transmission oil service is due.
g263439
Figure 27
1.
Hydraulic Trans Oil
3.
Remaining hours until
service
2.
Reminder display
4.
Reset
10