Troubleshooting
Problem
Possible Cause
Corrective Action
1. There is a lack of flow and pressure to
the eductor system.
1. Increase the pump speed. Turn the
agitation throttling toward the closed
position.
2. The outlet/Inlet hose is obstructed.
2. Disassemble and remove any
obstructions.
The eduction rate is low.
3. Fittings with elbows or other
flow-restrictions are in the eductor
outlet.
3. Use only sweeping turns with flexible
hoses.
1. The bottle rinse nozzle is plugged or
clogged.
1. Disassemble the rotary portion of the
nozzle from the lower valve assembly
and back flush until the nozzle ports
are clear of debris.
There is no rinsing or flushing action.
2. The flush tee is plugged or clogged.
2. Disassemble the flush tee and clean
until the nozzle ports are clear of
debris.
1. The fittings are damaged.
1. Check for cracks in the fitting. Replace
the fitting if necessary.
There are leaks at the fittings.
2. The thread sealant is worn.
2. Disassemble and seal the joint with
joint seal compound if a leak occurs on
the threads.