Electrical System
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cell specific gravity is less than 1.225, charge the bat-
tery. Charge at the recommended rate and time giv-
en in Charging or until all cells specific gravity is
1.225 or greater with the difference in specific gravity
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
3. Perform a high−discharge test with an adjustable
load tester.
This is one of the most reliable means of testing a battery
as it simulates the cold−cranking test. A commercial bat-
tery load tester is required to perform this test.
CAUTION
Follow the manufacturer’s instructions when us-
ing a battery tester.
A. Check the voltage across the battery terminals
prior to testing the battery. If the voltage is less than
12.4 VDC, recharge the battery.
B. If the battery has been charged, apply a 150 amp
load for 15 seconds to remove the surface charge.
Use a battery load tester following the manufactur-
er’s instructions.
C. Make sure battery terminals are free of corrosion.
D. Measure the temperature of the center cell.
E. Connect a battery load tester to the battery termi-
nals following the manufacturer’s instructions.
Connect a digital multimeter to the battery terminals.
F. Apply a test load of one half the Cranking Perfor-
mance (see Battery Specifications) rating of the bat-
tery for 15 seconds.
G. Take a voltage reading at 15 seconds, then re-
move the load.
H. Using the table below, determine the minimum
voltage for the cell temperature reading:
Minimum
Voltage
Battery Electrolyte
Temperature
9.6
70
o
F (and up)
21.1
o
C (and up)
9.5
60
o
F
15.6
o
C
9.4
50
o
F
10.0
o
C
9.3
40
o
F
4.4
o
C
9.1
30
o
F
−1.1
o
C
8.9
20
o
F
−6.7
o
C
8.7
10
o
F
−12.2
o
C
8.5
0
o
F
−17.8
o
C
I. If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
Summary of Contents for 30411
Page 1: ...Form No 03116SL Rev G Groundsmaster 4100 D Model 30411 Original Instructions EN...
Page 4: ...NOTES _...
Page 6: ...Groundsmaster 4100 D This page is intentionally blank...
Page 8: ...Groundsmaster 4100 D This page is intentionally blank...
Page 14: ...Groundsmaster 4100 D Page 1 6 Safety This page is intentionally blank...
Page 16: ...Groundsmaster 4100 D Page 2 2 Product Records and Maintenance Equivalents and Conversions...
Page 22: ...Groundsmaster 4100 D Page 2 8 Product Records and Maintenance This page is intentionally blank...
Page 42: ...Groundsmaster 4100 D Page 3 20 Kubota Diesel Engine Rev A This page is intentionally blank...
Page 48: ...Groundsmaster 4100 D Hydraulic System Page 4 6 This page is intentionally blank...
Page 126: ...Groundsmaster 4100 D Hydraulic System Page 4 84 This page is intentionally blank...
Page 190: ...Groundsmaster 4100 D Page 5 36 Electrical System This page is intentionally blank...
Page 226: ...Groundsmaster 4100 D Page 7 8 Chassis This page is intentionally blank...
Page 231: ...Groundsmaster 4100 D Cutting Deck Page 8 5 This page is intentionally blank Cutting Deck...
Page 235: ...Groundsmaster 4100 D Cutting Deck Page 8 9 This page is intentionally blank Cutting Deck...
Page 246: ...Groundsmaster 4100 D Cutting Deck Page 8 20 This page is intentionally blank...
Page 248: ...Groundsmaster 4100 D Electrical Diagrams Page 9 2 This page is intentionally blank...
Page 255: ...Page 9 9 Groundsmaster 4100 D Main Wire Harness...
Page 257: ...Page 9 11 Groundsmaster 4100 D Engine Wire Harness D4 D2 D6...
Page 259: ...Page 9 13 Groundsmaster 4100 D Front Wire Harness D7 D8 D5...
Page 261: ...Page 9 15 Groundsmaster 4100 D Cutting Deck Wire Harnesses...
Page 262: ......