6
Important
Whenever the cutting unit has to be tipped
to expose bedknife/reel, prop up rear of cutting unit to
make sure nuts on back end of bedbar adjusting screws are
not resting on work surface (Fig. 4).
1
2
Figure 4
1.
Prop (not provided)
2.
Bedknife adjusting screw
nut (2)
4. All cutting units are shipped with the counter weight
mounted to the left end and the motor mount and drive
coupler mounted to the right end of the cutting unit. To
mount the cutting unit in the right front position, on the
Greensmaster 3250–D proceed as follows:
A. Remove the 2 capscrews securing the counter
weight to the left end of the cutting unit. Remove
the counter weight (Fig. 5).
1
Figure 5
1.
Counter weight
B. On right end of cutting unit, remove plastic plug
from bearing housing (Fig. 6).
C. Remove the 2 allen head screws securing the motor
mount to the right end of the cutting unit. Remove
the motor mount (Fig. 6).
1
3
2
Figure 6
1.
Motor mount
2.
Plastic plug
3.
Allen head screw (2)
D. Remove the snap ring securing the drive coupler in
the reel tube (Fig. 7). Remove the drive coupler.
1
2
Figure 7
1.
Snap ring
2.
Drive coupler
E. Apply grease to the inside diameter of the drive
coupler. Install the drive coupler to the left end of
the cutting unit reel tube with a snap ring (Fig. 5).
F. Install the motor mount to the left end of the cutting
unit with the (2) allen head screws previously
removed (Fig. 6). Torque screws to 12–15 ft–lbs.
(16–20 N
⋅
m).
G. Install the counter weight to the right end of the
cutting unit with the screws previously removed.