INSTALLATION − DECO 20a / DEC0 26a / DECO 20e / DECO 26e
300561 en − 05/08
Chap. 3.10.2 /26
3.10 PNEUMATICS INSTALLATION
3.10.1Air Quality Specification
.
Caution !
The air supplied to the machine must be absolutely dry and oil-free.
Fit an air drier at the circuit input following the water/oil content in the
air system, to avoid malfunctioning or breakdowns of the machine.
Feature
Notes
Data
Air quality:
according to:
ISO 8573 − 1
Quality class:
workshop standard:
4
Size grading:
max.:
15
μ
m
Mass concentration:
8 mg/m
3
Pressure dew point:
max.:
+ 3
°
C
Oil content:
max.:
5 mg/m
3
For STANDARD PNEUMATICS and PICKOFF SPINDLE PNEUMATICS,
follow this note:
⇒
Note :
For more details, consult your operating instructions entitled :
OPERATION & MAINTENANCE.
3.10.2Pneumatical connection
(1)
(2)
(3)
LOCATION
Item
Description
1
Connector for blow−out gun
2
Pneumatic supply of the customer
3
Connector for bar loader