INSTALLATION − DECO 20a / DEC0 26a / DECO 20e / DECO 26e
300561 en − 05/08
Chap. 3.6.1 /17
Version 0018 & 0020
XS60
XS−−
XS94
XS42
(1)
(2)
RS232
LOCATION OF ELEMENTS
Ref.
Description
QS0
Main Switch
XS60
Fire protection system
XS94
Barfeeder socket, fixed
XS94
Barfeeder socket, fixed
XS42
Interface socket for pump, cooling.
(1)
Reserve
(2)
Socket for eternet
TM1
Autotransformer (if required)
TC1
Mains voltage transformer inside lathe’s enclosu-
re
XS1
Single phase current socket 230V 50Hz
3.6.1 Installation Characteristics
Feature
Notes
Data
Lathe power:
Average effective power:
(acc. to lathe application)
10 kW approx.
Installed power:
14 kVA approx.
Mains tolerances:
rated voltage:
frequency:
+/−10%
+/−1 Hz for 50/60 Hz
Main circuit-breaker:
at machine input
32 A
Δ
See also your instructions: SAFETY REGULATIONS DECO 2000