background image

1N15-002

 

Pirate Blasta Installation Manual V1 03/03

3. Repeatedly press the MODE button until the display shows:

PRIME PUMP

PRESS & HOLD ▲

4. Ensuring that no personnel are in the play area press and hold the UP button

until a constant stream of water is present at all guns. Release the UP button,
the pump is now primed.

Note!

In   the   next   section   you   will   be   guided   through   the   procedure   for   setting
various parameters required to operate the game. The following information
will prove useful.
The bottom line of the display might differ from the illustration in this manual
when a value is displayed. The actual value displayed will be the figure used
in the factory test.
If a value and the up and down arrows are flashing this signifies that the
flashing value may be changed by pressing the UP or DOWN buttons.
If just the up and down arrows are flashing this signifies that the feature on
the   top   or   bottom   line   of   the   display   may   be   selected   by   pressing   the
appropriate UP or DOWN button.
More detailed instructions regarding the control electronics will be found in
the user manual supplied with the game.

Setting the vend price:

1. Referring to diagram 3, press the MODE button repeatedly until the display

shows:

VEND PRICE

£00.00

2. Press and 

hold

 the MODE button until the display changes to:

VEND PRICE       ▲

CHANGE CODE  ▼

Note!

The system  has  the facility   to  protect  the  vend  price  setting with  a  code
number to prevent unauthorised alteration. Do not set or alter the code at this
time.

3. Press the UP button to select the top option VEND PRICE. The display will

now show VEND PRICE on the top line with the sign for the currency in use

©Tornado International Ltd. 2003

-8-

Confidential

Summary of Contents for Fire Blasta

Page 1: ...1N15 002 Pirate Blasta Installation Manual V1 03 03 Fire Blasta Installation Manual Tornado International Ltd 2003 1 Confidential ...

Page 2: ...ept Unit Sales 44 0 121 773 1827 Katie Roberts Comments 44 0 121 773 1827 Stuart Bland Addresses Head Office Sales Office Production Tornado International Ltd Unit 20 Stirchley Trading Estate Hazelwell Road Stirchley Birmingham B30 2PF United Kingdom Tel 0 121 773 1827 Email sales tornado uk com A Member of the Tornado International Leisure Group Tornado International Ltd 2003 2 Confidential ...

Page 3: ... any questions with regard to the correct installation or operation of the product please contact Tornado International Ltd Contact information will be found on page 2 of this manual Warning Important Please Read This This manual is provided in good faith and is believed to be accurate Because Tornado International have no control over the manner in which the product is used owners users and insta...

Page 4: ...ating area before opening 4 The crates should be opened carefully and the contents removed Be sure to check in the bottom of the crates in amongst any packaging to ensure that all of the items have been removed before the crates are discarded If possible leave the crates on site until the product has been assembled and tested If any damage was noted on the outside of the crates the items next to t...

Page 5: ...screwdriver Medium flat screwdriver Medium cross point screwdriver Power drill 3 4mm drill bit Sharp knife Sealant dispensing gun Sufficient 15mm copper pipe and fittings or flexible hose and fittings to reach from the water supply to the left hand rear of the unit Additional power supply cable 3 core x 1 25sqmm if the power supply is over 2M from the left or right rear corner of the unit 10off ea...

Page 6: ...ssembled with water in the tank and be ready to connect the power and test the unit Note The sealant used in the construction of the unit should be allowed to set before proceeding The time taken for this will depend on the ambient temperature and humidity Test a small area with your finger to ensure it is set before proceeding 4 If the game is to be used in the United Kingdom connect the supplied...

Page 7: ...lows Open the pump house door and referring to Dia 2 locate and remove the filling plug Using a suitable container completely fill the pump chamber with clean water and replace the plug Dia 2 The pump filling plug 2 Locate the Aqua Blasta control electronics in the pump house lid Dia 3 Dia 3 The control electronics Tornado International Ltd 2003 7 Confidential ...

Page 8: ...t the flashing value may be changed by pressing the UP or DOWN buttons If just the up and down arrows are flashing this signifies that the feature on the top or bottom line of the display may be selected by pressing the appropriate UP or DOWN button More detailed instructions regarding the control electronics will be found in the user manual supplied with the game Setting the vend price 1 Referrin...

Page 9: ...ting of 1 6 minutes will mean the game will last for 1 minute and 36 seconds Setting the attract delay time The attract delay time is the amount of time the game must stand idle before the attract mode is activated The attract mode turns on each of the guns for a short time in a preset pattern The noise and visual pattern serve to attract customers passing the game 1 Press the MODE button once the...

Page 10: ...e is working A short pulse of water should issue from guns number 1 to 4 in turn then from guns 1 4 together then guns 2 3 together and finally all four guns together The unit is now tested and ready to use Please refer to the User Manual to change any of the settings or to apply the protection code Full details of the game and cash reporting features of Pirate Blasta can also be found in the manu...

Page 11: ...1N15 002 Pirate Blasta Installation Manual V1 03 03 Appendix A Sheets 1 to 17 Tornado International Ltd 2003 11 Confidential ...

Reviews: