Digital program switch menu
14
EN
OTHER
PARAMETERS
BATTERY
INTERLOCK
AUTOM. RECLOSING
TIME
PARTIAL RECLOSING
TIME.
AUTO.RECL.TIME
CLOSING SEAL
SAFETY SENSOR LOGIC
PARTIAL OPENING.
EB1 LOGIC
EB1 MODE
EB2 LOGIC
PHARMACY
PHARMACY OPEN
: automatic reclosing time.
Adjustable from 0 to 60 seconds.
: automatic reclosing time after key impulse
Adjustable from 0 to 60seconds
: Adjustable from 0 to 4 (disables closing seal, enables the
push&go function
: Safety sensor logic:
NOS: normally open without test
NCS: normally close without test
NC test : normally close with test
: adjustable from 5 to 95% of the door opening
: Electric lock logic 1:
OFF: Disabled
CT: Block if powered
ST: Block if not powered
: Electric lock mode 1 :
B1: Closed
B2: Closed,exit only,entry only
B3: Closed,exit only,open only,automatic
: enables or disables the pharmacy function
: pharmacy opening setting. Adjustable from 2 to 20cm.
Important
: regulate in relation to the position of electric lock 2
: Battery operation mode:
NC: Battery not installed
AP: opens in case of power outage on mains
AC: opens except when in closed mode
ACUE: opens except when in closed mode, exit only, entry only, closes, pharmacy
CP: closed
CN: continuous operation
NO test: normally open with test
: YES ( possible to enable 2 pairs of doors 1-2 and 3-4 )
: NO
PARAMETERS
NUMBERING
RADIO
EX PASSWORD
: Allows you to number the doors connected from
1 to 4 *
ACQUIRE
LANGUAGE
: Allows you to select the language between:
italian
english
french
spanish
: Allows you to add up to 8 radiocontrols. Possibility of installation
only
with a motor board equipped with optional radio module.
: Allows you to change the default expert password
(default 2426 )
DELETE
: Allows you to eliminate all the
radiocontrols
: partial reclosing time.
Adjustable from 0 to 60 seconds.
OTHER
- If you are using the Topp
TS1
4-channel remote control, press
the second key (Close Function).
- If you are using the remote radio control kit, Top
TR8
, press the
smooth part of the first key (Open Function)
To program the radio control devices (up to 8):
In case of lengths in excess of 20m we recommend using a
shielded type cable.
*Doors numbering:
(if it has not been done before, this
procedure is accessible also from the home screen by pressing
' arrow down ' for 4sec in case of communication error)
2.Press, one by one, the 'ENTER' key on the correspondent
door's motor board.
The doors must be connected as shown (see fig. No.10). The
wires to be connected are GND (2), Serial A (3) and Serial B (5).
To program:
1.Enter the number of the connected doors
partial
EMERGENCY LOGIC
:Setting emergency opening.
ANTIPANIC LOGIC
: Setting antipanic opening.
:N.O. Normally open
:N.C. Normally closed
:N.O. Normally open
:N.C. Normally closed
To exit from the DOOR NUMBERING press
The password remains active for 1 minute once out of the menu,
then it has to be inserted once again.
EB6
(Non available for T150-T240)
(Non available for T150-T240)
(Non available for T150-T240)
SEE EB1 LOGICA
18
EN
MODE 2
Entry only:
«Entry only», operates like «Entry only»
if you have the TS2, MS1 control accessories
.
Wings free:
«Entry only», operates like «Wings free»,
if you have the TS2, MS1 control accessories
: Change the standard mode of operation of the Ts2, MS1 accessory
buttons.
:
allows use of MODE 2
if the automation board is set up for the «Wings free» function.
POWER OFF
EB12
(Non available for EB12)
Command active only in the case of battery operation
(without external power supply). Turn off the automation
and the digital selector..
FIRST START UP