background image

VoxiPlus 

Advanced 

INSTALLATION MANUAL

 

 

© 2008 TOPEX S.A. 

 

 

 

 

 

 

 

 

    page     

44

 

 

 

7 TECHNICAL 

SPECIFICATIONS 

 

Product Name 

TOPEX VoxiPLUS  

Mechanical Built 

Metal case, compact version or 2U rack with four slots for plug-in cards 

Processor card (PGVoIP) 

Card for main processor and VOIP (2 VoIP interfaces)  
Can also feature two interfaces for E1 digital trunks 

E1 digital trunks 

The two E1 interfaces are according to the G.703 standard and the frame 
structure si according to G.704. The line impedance is 75 0r 120 ohm, 
symmetrical. The internal clock generator may work alone or synchorniyed 
with any external criteria, if you need to connect together several equiments. 
The interfaces are full duplex and support the protocols PRI or E1 CAS.  

Ethernet capacity 

1 LAN interface on the PGVoIP card 
1 WAN interface on the PGVoIP card 
Connector types: RJ45 – 10/100 BaseT 

Mobile Card 

Up to 4 Quad Band GSM / UMTS  modules 
1 RF(built in splitter) or 4 RF circular connectors for mobile antennas 
4 SIM cards per GSM board 
Aditionally, it may also feature four ISDN BRI digital interfaces  

HSDPA engine 

Networks frequencies:  
850/1900/2100 MHz WCDMA Power class 3 (+24dBm) 
850/900MHz GSM/GPRS/EDGE GSM Power class 4/ EDGE E2 
1800/1900 MHz GSM/GPRS/EDGE GSM Power class 1 /EDGE E2 

GSM engine 

Networks frequencies:  
900 / 1800 MHz & 850 / 1900 MHz 

Configurable Universal 
Card for FSX / FXO ports 

MPAI motherboard card with up to 8 FSX / FXO ports in different 
configurations 
The SLIC for the ports are available as daughterboards 
RJ45 connectors for all 8 interfaces 
Direct software upgrade  

FSX ports 

Electrical characteristics of the line circuit:  
- line current limited to 30 mA  
- line resistance for which a 20mA loop current is assured: 1,7Kohm 
- insulation resistance for which the closed loop situation is no longer 
detected: 20 K ohm 
- galvanic insulation between the phone line and the low voltage command 
circuits  

Codecs used 

G.711 – up to 60 voice channels 
G.723.1, G.729ab – up to 30 voice channels 

Signaling protocols 

SIP v.1, v.2 
H.323 v.2, v.4 

Mobile Antennas 

Different individual antennas or collective antennas for the corresponding 
frequency bands 

Power Supply 

230VAC / 50MHz 
When FXO or FXS ports are required, the equipment must be fitted with an 
additional power supply for the voltage  -48V 

DC

Operating temperature 

5

o

 50

o

C  

÷

Humidity 

10% - 85 % without condensing 

 

Summary of Contents for VoxiPlus

Page 1: ...TOPEX VoxiPlus Advanced VoIP PRI BRI GSM Gateway Installation Manual 2009...

Page 2: ...ty This allows TOPEX to have maximum control of all the processes involved in the complex operations related to high technology electronic manufacturing At the present time the Research and Developmen...

Page 3: ...bile antennas 22 2 7 Power Supply 23 3 VoxiPlus Advanced INSTALLATION 24 3 1 Mounting hardware installation 24 3 2 Connecting the cables 24 3 3 Connecting the telephony cables 26 3 4 Connecting the an...

Page 4: ...not part of the product Do not disassemble the product Contact TOPEX service department if service or repair is required WEEE Directive Compliance WEEE Directive This symbol applied on your product or...

Page 5: ...uct performing the operations described bellow 1 The battery is comprised by PC104 component of processor card For removal open the product case or extract the card and identify the battery and its pl...

Page 6: ...hannels Figure 1 Diagram for VoxiPLUS The board of the equipment can be enabled to make up to four calls simultaneously from SIP phones to GSM network and from GSM network to IP phones TOPEX VoxiPLUS...

Page 7: ...annels available to 12 Capacity Up to 64 VoIP channels four ISDN BRI or two ISDN PRI interfaces eight FXS or FxO ports per MPAI card maximum three cards four GSM or UMTS channels 4 SIM cards per GSM c...

Page 8: ...bine these for instance 16 FxS and 8 FxO IP PBX main features Up to 120 registered SIP clients Call Hold Call Waiting Call Forward Busy No Answer Offline Always Only for Specific List of Numbers Call...

Page 9: ...em The TOPEX VoxiPLUS equipment comes with an OAM program that runs on a PC to monitor in detail operation of the remote system for detailed diagnostics etc The main features of the TOPEX VoxiPLUS equ...

Page 10: ...ast Cost Router is flexible enough to help you set rules for GSM calling at the lowest possible operation costs Routing calls Routing is the process of selecting paths in a network along which to send...

Page 11: ...or Mobile VoIP to GSM routing An incoming call from the IP network VoIP call using SIP or H323 protocol is analyzed by the Least Cost Router LCR The LCR decides which line the call shall use for going...

Page 12: ...er routing level e g in a PBX If the VoIP telephones used are equipped with the Calling Line Identification Presentation CLIP function either the internal number of the gateway output line used for th...

Page 13: ...lity to configure the equipment based on user s requirements The main function of the TOPEX VoxiPLUS equipment is VoIP GSM Gateway SIP Trunking The hardware structure contains Mechanical build metal c...

Page 14: ...p to 4 GSM channels advanced extended configuration for plug in cards with different combinations of FXS and FXO ports and maximum 12 GSM channels TOPEX VoxiPlus is integrated in 2U rackable equipment...

Page 15: ...ction IP interfaces LAN and WAN GSM interfaces Telephony interfaces FXS or FXO Thus the 2U version of TOPEX VoxiPLUS may feature up to 12 Quad Band GSM or UMTS modules that allow the easiest connectio...

Page 16: ...the status of the device The LED s significance is detailed in chapter 2 5 Status Monitoring A pair of RJ45 connectors for E1 trunks labeled E1 A and respectively E1 B 2 4 2 GSM UMTS Card The GSM car...

Page 17: ...ombiner so it features one antenna connector for each module thus four RF connectors per card 2 4 3 Other Interfaces The VoxiPLUS gateways come equipped either with 2E1 interfaces or with four interfa...

Page 18: ...ay be configured as 8 eight FXS or FXO ports but only for 4 four E M ports The piggy back SLIC system ensures versatility and ease of repair you purchase a MPAI card then according to the requirements...

Page 19: ...l of the MPAI card PIN SIGNALL Description 1 Test Signal Input 2 GND 3 Not used 4 A 5 B Line FXS or FXO 6 Not used 7 GND 8 Test Signal Output For easy updating of the firmware of the MPAI card it feat...

Page 20: ...x kernel is running It pulses faster or slower depending upon the operations performed by the embedded software The yellow LED lights up or blinks to show reading from the non volatile memory XD Card...

Page 21: ...om the board is selected 1500 100 100 100 Module unregistered to the mobile network the SIM emulator is selected 100 1500 Module registered to the mobile network the SIM from the board is selected 100...

Page 22: ...ctive mobile network Also no combiners means less attenuation so the level of the RF signal of the mobile networks will be higher If you don t need directional antennas targeted to a specific location...

Page 23: ...e non insulated washer is the power grounding used for safety electro security thus it is always present Its purpose is to supplement double the safety grounding of the power plug which is a three pin...

Page 24: ...g enough to hold the weight of the equipment together with its cables power supply Ethernet Serial telephone connections A good place for equipment installation is represented by a desk table or shelf...

Page 25: ...sover cable no matter if you are connecting to a LAN switch hub or a in case of connecting the equipment directly to the Ethernet port of your computer The second kind of link is highly recommended wh...

Page 26: ...RJ 45 connectors labelled E1 A respectively E1 B on the right side of the front panel of the PG VoIP card The cable must have the following pinout Pins 1 orange with white and 2 orange of the RJ 45 c...

Page 27: ...antenna base usually the mounting bracket is grounded Grounding of the antenna base improves reception of the mobile networks At the same time a grounded antenna is indirectly protected from the effe...

Page 28: ...motors or heaters The antenna must be mounted in such was as the minimum distance to human beings to be of at least 20 cm in order to avoid the human exposure to its radiations Remember that the equi...

Page 29: ...rtion and also when you want to replace change the existing SIM card with a new one Warning When inserting extracting the SIM card the equipment must be powered off to avoiding damaging the internal m...

Page 30: ...Advanced INSTALLATION MANUAL 2008 TOPEX S A page 30 Figure 21 Connecting the mains power cable Following the power up of the TOPEX VoxiPlus the red LED located on the front panel of the equipment mus...

Page 31: ...gb4rf user name tpxadm password Permissions for advanced user user name root password 91qwerty19 b For Ethernet connection IP address on the LAN side 192 168 110 15 must be changed with a private IP a...

Page 32: ...connection Verify that the special serial cable is properly connected Set the serial port COM properties of your computer to match the parameters of the VoxiPlus serial connection Bits per second 1152...

Page 33: ...LLATION MANUAL 2008 TOPEX S A page 33 From Device Manager select Ports COMx where x is the first available serial port of your computer in this example COM1 was used Configure the Properties for respe...

Page 34: ...nt You must use a serial communication program terminal emulator to connect to the Linux console of the VoxiPlus equipment The programs may be HyperTerminal under Microsoft Windows TELIX for DOS Windo...

Page 35: ...it for instance TopexVoIPGateway select the COM port where you have connected the serial cable like COM1 in the example shown here Set the initial communication parameters for the serial link Bits pe...

Page 36: ...ory type ls to make a copy of the network file in order to edit it safely you type cp network network1 to view a file you use the cat command to display or change the time date use date and so on If y...

Page 37: ...livered on a CD included in the TOPEX package The PC where you install the OAM application must fulfill these minimum requirements Processor with 1 GHz frequency 128 MB RAM memory 20 GB hard disk capa...

Page 38: ...configuration After the successful installing the OAM application you must add the The RGW equipments into the configuration for this follow the next instructions Note The OAM application allows you t...

Page 39: ...directory in the following shape cfg_xxxxxxx where directory is the name typed in the Directory field The folder will be created on HDD in the directory where the executable gwconfig exe is located A...

Page 40: ...IP communication this setting allows if is checked a dialup connection to be established The Dialup Connection must be created from Windows from Dial Up Networking and the connection name must not co...

Page 41: ...ced INSTALLATION MANUAL 2008 TOPEX S A page 41 Save the configuration for new added system Press the Save button for the window shows in figure 1 to complete the adding of a new VoxiPlus system via OA...

Page 42: ...mobile telephony network GSM UMTS One or several subscribers registered to an IP PBX equipment initiate calls to the mobile telephony network These calls are transmitted to the VoxiPLUS equipment whic...

Page 43: ...s through the IP network The costs savings are achieved by the transport of call through the IP network instead a direct call between two different mobile networks or between two mobile networks from...

Page 44: ...PA engine Networks frequencies 850 1900 2100 MHz WCDMA Power class 3 24dBm 850 900MHz GSM GPRS EDGE GSM Power class 4 EDGE E2 1800 1900 MHz GSM GPRS EDGE GSM Power class 1 EDGE E2 GSM engine Networks...

Page 45: ...posure to sun radiation must be avoided Must NOT be used in a flammable or explosive environment or in locations where toxic or flammable gases may be accumulated Mechanical shocks must be avoided Mus...

Page 46: ...J45 located on the front panel of the TOPEX VoxiPLUS The power supply cable that must be inserted on the special connector DIN located on the back panel of the equipment Notice The supply cable is alw...

Page 47: ...VoxiPlus Advanced INSTALLATION MANUAL 2008 TOPEX S A page 47 Note The other pins are not used Figure 25 The pin out for the serial cable...

Page 48: ...M network stat 2 the module is not registered but is trying to register to a GSM operator stat 3 the registration is not allowed stat 4 unknown stat 5 the module is registered and he has roaming AT CL...

Page 49: ...number will be displayed CLIP calling number xxx The GSM module should be responding with OK ATH The command is used to end a call The GSM module is responding with OK AT COPS This command will detec...

Page 50: ...fine a time interval ttt after which a SIM will be blocked sss is the sim coresponding value You may specify a range of SIM cards values Value of sss may be computed as follows number of card shown in...

Page 51: ...p to TCP protocol Transmission Control Protocol to put the packets back in the right order GSM Acronym for Global System for Mobile Communications The dominant digital cellular technology for mobile t...

Page 52: ...hanged UDP Acronym for User Datagram Protocol It is a simpler protocol than TCP that corresponds to the transport layer of the ISO OSI model UDP converts the messages generated by the application into...

Page 53: ...e 13 LED s and SIM location for GSM card 21 Figure 14 Magnetic antenna 22 Figure 15 Location of the power receptacle and mains switch 23 Figure 16 Connecting the serial cable 25 Figure 17 LAN connecti...

Page 54: ...ual may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without the prior written permission of the company TOPEX S A...

Reviews: