16. SETTING-OUT MEASUREMENT
86
4. Enter values and press
[OK]
in step 3 to display
the screen at right.
5. Sight the target and press
[MEAS]
. Measurement
begins and the measurement results are
displayed.
6. Press
[REM]
to start REM measurement.
The distance (height difference) and direction to
move the target until the sighting point and setting
out point are located is displayed on the FX.
Press
[STOP]
to stop measuring.
Find the setting-out point by moving the telescope
until the distance to the setting-out point reads 0m.
• Movement indicator (Red indicates that target
position is correct)
Q
: Move the telescope near the zenith
H
: Move the telescope near the nadir
HQ
: Telescope direction is correct
C
For details of other movement indicators:
"16.2 Distance Setting-out Measurement"
step 6
Arrows indicate direction to move