21. WARNING AND ERROR MESSAGES
126
Input over 3 letters !
The input password consists of less than 3 characters. Input a password at least 3 characters in
length.
Need base pt. obs
During REM measurement, the observation of the target was not completed normally.
Reset and sight the prism and perform measurement again.
Need 1st obs
During missing line measurement, the observation of the starting position was not completed
normally.
Sight the starting position accurately and press
[MEAS]
to perform the measurement again.
New password Diff.
During new password setting, the passwords input twice are different. Input new password twice
correctly.
No solution
The calculation of the instrument station coordinates during resection does not converge.
Access the results and if necessary, perform the observations again.
Out of range
During gradient % display, the display range (less than ± 1000%) has been exceeded.
During REM measurement, either the vertical angle has exceeded horizontal ±89° or the
measured distance is greater than 9999.999m.
Install the instrument station far from the target.
The instrument station coordinates calculated during resection are too high.
Perform the observation again.
During area calculation, results exceeded the display range.
Please input an address consisting of 12 hexadecimal characters (0 to 9, A to F)
The
Bluetooth
address is not input correctly for
Bluetooth
communication. Input the
Bluetooth
address with 12 characters of 0 to 9 or A to F.
Signal off
The reflected light is not observed when distance measurement begins. Or, during measurement,
the reflected light has weakened or is blocked.
Either sight the target again or, when using a reflective prism, increase the number of reflective
prisms.
Target not found !!
The prism cannot be found within the Search area range.
Reset and sight the prism and perform measurement again.
Temp Rnge OUT
FX is outside useable temperature range and accurate measurement cannot be performed.
Repeat measurement within the appropriate temperature range.