Configuration
Topcon
HiPer GD and HiPer GGD Operator’s Manual
2-24
Note that a log file opens immediately after turning AFRM on.
This startup file is not considered a file rotation event; the
AFRM counter will not decrement.
Values are 0 to [2
31
-1]. The default value is 0 (zero). Zero
means that an unlimited number of log files will be created.
NOTICE
The receiver’s memory holds up to 512 files.
• Files (remain) – specifies the number of files left for the
receiver to create in AFRM.
Values are 0 to [2
31
-1]. The default value is zero.
• Automatically remove old files – when no free memory is
available to log data, automatically removes the earliest log file.
If this parameter is enabled, your receiver will erase the file
with the earliest file creation time/date. AFRM must be enabled
to use this FIFO (First-In, First-Out) feature.
The default value is off (disabled).
FN Key Mode parameter
You use these two radio buttons to program how the receiver
will react when pressing the FN key.
• LED blink mode switch – pressing FN will toggle between the
MINTER’s normal/extended information modes and start/stop
data recording of Static survey.
– FN pressed less than 1 second: changes the information mode
(Normal or Extended Information (EI) Modes).
– FN pressed from 1 to 5 seconds: starts or stops recording
(Static post-processing mode).
• Occupation mode switch – pressing FN (less than one second)
will insert into the corresponding log file a message indicating
that the survey type has been changed from static to kinematic,
Summary of Contents for HiPER GD
Page 1: ...PRECISION GPS HiPer GD HiPer GGD HiPer GD HiPer GGD Operator s Manual ...
Page 2: ......
Page 4: ...ECO 2101 ...
Page 12: ...LIst of Figures Topcon HiPer GD and HiPer GGD Operator s Manual viii Notes ...
Page 22: ...Preface Topcon HiPer GD and HiPer GGD Operator s Manual xviii Notes ...
Page 42: ...Introduction Topcon HiPer GD and HiPer GGD Operator s Manual 1 20 Notes ...
Page 146: ...Troubleshooting Topcon HiPer GD and HiPer GGD Operator s Manual 5 10 Notes ...
Page 162: ...Specifications Topcon HiPer GD and HiPer GGD Operator s Manual B 14 Notes ...
Page 166: ...Safety Warnings Topcon HiPer GD and HiPer GGD Operator s Manual C 4 Notes ...
Page 170: ...Warranty Terms Topcon HiPer GD and HiPer GGD Operator s Manual E 2 Notes ...
Page 176: ...Index Topcon HiPer GD and HiPer GGD Operator s Manual Index Notes ...
Page 177: ...1 866 4TOPCON www topconpositioning com Notes Notes ...
Page 178: ...Topcon HiPer GD and HiPer GGD Operator s Manual Notes Notes ...
Page 179: ......