In EIM, the STAT LED blinks seven times per cycle. Each
blink could be orange, red, or green.
• Orange – information for test unavailable.
• Green – receiver passed the test.
• Red – receiver failed the test.
1. To switch to EIM, press and quickly release (within one
second) the FN key on the MINTER.
2. Watch for the delimiter double-blink. With good
receiver, antenna, and observation conditions, all blinks
should be green within 15 minutes of powering on.
• Green – ok
• Orange – wait
• Red – some tests failed
3. To switch back to normal, press the FN key.
Table 4-2. Signal-to-Noise (S/N) “Good” Ratios
CA/L1
P/L1
P/L2
GPS
51
39
39
GLONASS
51
49
40
Summary of Contents for HiPER GD
Page 1: ...PRECISION GPS HiPer GD HiPer GGD HiPer GD HiPer GGD Operator s Manual ...
Page 2: ......
Page 4: ...ECO 2101 ...
Page 12: ...LIst of Figures Topcon HiPer GD and HiPer GGD Operator s Manual viii Notes ...
Page 22: ...Preface Topcon HiPer GD and HiPer GGD Operator s Manual xviii Notes ...
Page 42: ...Introduction Topcon HiPer GD and HiPer GGD Operator s Manual 1 20 Notes ...
Page 146: ...Troubleshooting Topcon HiPer GD and HiPer GGD Operator s Manual 5 10 Notes ...
Page 162: ...Specifications Topcon HiPer GD and HiPer GGD Operator s Manual B 14 Notes ...
Page 166: ...Safety Warnings Topcon HiPer GD and HiPer GGD Operator s Manual C 4 Notes ...
Page 170: ...Warranty Terms Topcon HiPer GD and HiPer GGD Operator s Manual E 2 Notes ...
Page 176: ...Index Topcon HiPer GD and HiPer GGD Operator s Manual Index Notes ...
Page 177: ...1 866 4TOPCON www topconpositioning com Notes Notes ...
Page 178: ...Topcon HiPer GD and HiPer GGD Operator s Manual Notes Notes ...
Page 179: ......