1 NOMENCLATURE AND FUNCTIONS
1-3
V : 87
°
55'45"
HR: 180
°
44'12"
SD HD NEZ 0SET HOLD P1
↓
V : 87
°
55'40"
HR: 180
°
44'12" PSM 0.0
SD: 12.345 PPM 0.0
(m) *F.R
MEAS MODE VH HD NEZ
↓
Display
Contents
Display
Content
V
V-angle
(m)
Meter unit
V%
Percent grade
(f)
Feet unit
HR
H-angle right
F
Fine mode
HL
H-angle left
C
Coarse mode (1mm)
HD
Horizontal distance
c
Coarse mode (10mm)
VD
Relative elevation
R
Repeat measurement
SD
Slope distance
S
Single measurement
N
N coordinate
N
N-times measurement
E
E coordinate
ppm
Atmospheric correction value
Z
Z coordinate
PSM
Prism constant value
*
EDM working
NPM
Non-Prism constant value
NP
Non-prism mode
Battery Level Indicator
Refer to Section 2.4 “Battery Level
Indicator” for further information.
Rotation Indicator
Refer to Section 1.8 “ Rotating
Method” for further information.
Laser plummet is working.
(Only for laser plummet model)
1.2 Display
• Display
In general upper four lines display the measuring data, and the bottom line displays the soft key
function which is changed by the measuring mode.
• Contrast
The contrast and illumination of display window are adjusted by star ( ) key.
• Heater (Automatic)
The built-in heater keeps the display functional when the temperature goes below 0°C (32 °F). To
switch the heater ON or OFF, refer to Chapter 8 "PARAMETERS SETTING MODE". When the
heater is ON and the temperature goes below 0°C (32 °F), the heater automatically
adjust the temperature to the display to keep it operating.
• Example
Angle measurement mode
V-angle:
87º55’45”
H-angle:
180º44’12”
Distance measurement mode
Horizontal-angle:
87º55’45”
Horizontal distance:
180º44’12”
Relative elevation:
12.345m