4 STANDARD MEASUREMENT MODE
4-6
4.2.3 Distance Measurement (Continuous Measurement)
Make sure the mode displays angle measurement.
Operating procedure
Operation
Display
1
Collimate the center of prism.
2
Press [F1](SD) key or [F2]( HD )key.
*1), 2)
[Example] Horizontal distance mode
[F2]
The result are shown *3) to *6)
*1)
The following characters will be shown on the 4th line right hand corner of the display to
represent measurement mode.
F: Fine meas. mode, C: Coarse (1mm) meas. mode, c: Coarse (10mm) meas. mode.
R: Continuous (Repeat) meas. mode , S: Single meas. mode, N: N time meas. mode
*2) When EDM is working, the "* " mark appears in the display.
*3) The result is shown with buzzer sound.
*4) Measurement may repeat automatically if the result is affected by shimmer etc..
*5) To change single measuring, press [F1](MEAS) key.
*6) To return to the angle measurement mode, press [F3](VH) key.
V : 90
°
10'20"
HR: 120
°
30'40"
SD HD NEZ 0SET HOLD P1
↓
V : 90
°
10'20"
HR: 120
°
30'40" PSM 0.0
HD: < PPM 0.0
VD: (m) *F.R
MEAS MODE VH SD NEZ P1
↓
V : 90
°
10'20"
HR: 120
°
30'40" PSM 0.0
HD: 716.661 PPM 0.0
VD: 4.001 (m) *F.R
MEAS MODE VH SD NEZ P
1
↓
Summary of Contents for GPT-8000 Series
Page 89: ...5 PROGRAM MODES 5 28 ...
Page 124: ...11 SETTING ATMOSPHERIC CORRECTION 11 4 ...