8 PARAMETERS SETTING MODE
8-3
4.Stop Bit
1 / 2
Select the stop bit.
5.Delimit
ETX / CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
6.REC-A/B
A / B
Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
7.Protocol
OFF / ON
When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard
8.NEZ-REC
Std / Expand
Record coordinates in standard or Data with slope distance
and horizontal angle data.
For GPT-8000A series
The following settings are effective for standard measurement modes only.
You are requested to set each time of each application such as EXTERNAL LINK (in Program modes)
or other application software.
Serial port
.
Setting parameters for RS232C
Menu
Selecting Item
Contents
S.Port
RS232C / RC
Selecting serial port, RS-232C connector 1(6pins) or Remote
controller handle unit RC-2H.
Menu
Selecting Item
Contents
1.B. Rate
1200 / 2400 / 4800 /
9600
Select the baud rate.
2.Data. L
7 / 8
Select the data length seven digits or eight digits.
3.Parity
none / odd / even
Select the parity bit.
4.Stop Bit
1 / 2
Select the stop bit.
5.Delimit
ETX / CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
6.REC-A/B
A / B
Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
7.Protocol
OFF / ON
When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard
8.NEZ-REC
Std / Expand
Record coordinates in standard or Data with slope distance
and horizontal angle data.
9.Trk Stat
OFF / ON
Selecting additional information of utility to measuring data
such as tracking status or not.
If such utility is selected, electric circular level graphic will not
be displayed whenever tilted over.
OFF :No additional information
ON
:Additional information