3. Electronic gear setting
The encoder mounted encoder is 10000 pulses per revolution by setting the electronic gear parameters PA12, PA13
Any pulse equivalent can be obtained. Note: You can set any value for the numerator and denominator to get any ratio.
But it is best not to exceed the 1/50~50 range.
Table 7-1 Relationship between the number of input pulses and the number of revolutions
Input pulse number
Number of motor
revolutions
Electronic gear mol
-
ecule
PA12
Electronic gear
Sub PA13
Pules
PA12
PA13
10000
1
1
1
5000
1
2
1
3000
1
10
3
800
1
25
2
20000
1
1
2
1000
2/3
20
3
4000
3
30
4
Table 7-2 Relationship between input pulse frequency and rotation speed
Input pulse frequency
(Hz)
Motor speed (r/min)
Electronic gear mol
-
ecule
PA12
Electronic gear
Sub PA13
Frequency
PA12
PA13
300K
1800
1
1
500K
3000
1
1
100K
1200
2
1
100K
1800
3
1
50K
1000
10
3
200K
800
2
3
100K
300
1
2
Summary of Contents for SD300