![Topcnc SD300 Instructional Manual Download Page 81](http://html1.mh-extra.com/html/topcnc/sd300/sd300_instructional-manual_1128026081.webp)
•
according to the following table:
Parameter number
significance
Parameter value
Factory default
PA4
Control method selec
-
tion
3
0
PA20
Drive inhibit input is
invalid
1
0
•
After confirming that there is no alarm and any abnormal conditions, make the servo enable (SON) ON and the
RUN indicator light.
The motor is energized and is at zero speed.
•
Select “
” in the first layer by pressing the button, and press the Enter key to enter the JOG opera
-
tion mode.
When the JOG is running, the prompt is
the value unit is r/min, and the system is at speed.
Control mode, speed command is provided by the button. Press ↑ and hold, the motor runs at JOG speed, re
-
lease button
Key, the motor stops, keeps zero speed; press ↓ key and hold, the motor runs in reverse direction at JOG speed,
release the button,
The motor stops and keeps at zero speed. The JOG speed is set by parameter PA21 and the default is 120r/min.
Figure 7.8 JOG operation block diagram
•
l If the external control servo enable (SON) is inconvenient, you can set the parameter PA53 to 0001 to force the
servo enable.
(SON) ON is active and does not require external wiring to control SON.
4. Manual speed control operation
•
l Turn on the control circuit power supply (the main circuit power supply is temporarily not connected), the dis
-
play of the drive is lit, if an alarm occurs,
Please check the connection.
•
l Turn on the main circuit power and the POWER indicator lights up.
•
l Set the parameter values
Summary of Contents for SD300
Page 87: ......