11 Ordinary Maintenance
TO
MAINTAIN
THE
STATION
PERFECTLY
EFFICIENT,
IT
IS
NECESSARY
TO
CARRY
OUT
THE
ORDINARY
MAINTENANCE
THE
ABSENCE
OF
MAINTENANCE
RELEASES
THE
MANUFACTURER
FROM
ANY
RESPONSIBILITY
CONCERNING
THE
GUARANTEE.
EVERY
OPERATION
OF
ORDINARY
MAINTENANCE
MUST
BE
DONE
WHILE
THE
STATION
IS
DISCONNECTED
FROM
THE
ELECTRIC
POWER
SUPPLY.
EVERY
OPERATION
WHICH
IS
NOT
ORDINARY
MAINTENANCE
MUST
BE
DONE
BY
SPECIALIZED
AND
COMPETENT
OPERATORS
Periodically (according to the use), replace the dehydrating filter and the pump oil.
In any case, after 130 kg of gas recovered, a message of maintenance appears on the display - carry out at this
moment the maintenance of the station.
11.1 Pump Oil
Replace the pump oil after
100/150 hours
of working or at least
every year
even if the station is used occasionally.
The oil's replacement is indispensable also when the presence of contaminating substancies in the oil makes it
turbid; in this case the mechanical parts of the pump may be damaged irreparably.
Use mineral oil for vacuum pumps type
AV68I
. The amount needed is around
300 grams
.
11.1.1 Oil Refill
Insert new oil from the "B" cap, until arriving to the level shown in the "C" indicator.
11.1.2 Pump Oil Replacement
Discharge the oil from the "A" cap.
Insert new oil from the "B" cap, until reaching the level shown in the "C" indicator.
WARNING
DO
NOT
DISCHARGE
THE
OIL
IN
THE
ENVIRONMENT
BUT
DISPOSE
OF
IT
AS
A
SPECIAL
WASTE
ACCORDING
TO
THE
LAWS
IN
FORCE.
A
B
C
Replacement oil's
code
AV68I
Image 51 - The pump and its elements