OUTPUT INDICATOR LIGHT

Output indicator light (green) will remain ON during 

operation. However, when the green light starts flashing:
1.  Interval Flash once, low-voltage protection, engine 

speed low.

2.  Interval Flash twice, high temperature protection.
3.  Interval Flash 3 times, overload protection, too high a 

wattage load, check the appliance(s) wattage before 

using again.

4.  Interval Flash 4 times, short-circuit protection. The 

output power will be cut off should the generator is 

experiencing any of the faults that are mentioned 

above and the light will also go out.

SAFETY DEVICES

AC OUTLET

Your generator is equipped with an output indicator light, 

see above. When this light is goes out then the generator 

will produce NO POWER. 
To restart the power supply;
1.  Remove the appliance.
2.  Stop the generator, see page 12.
3.  Wait 2 minutes.
4.  Start generator, see page 11, ensure the green output 

indicator light is illuminated.

5.  Re - attach the appliance.
6.  If the output indicator light goes out and the output 

power stops then the attached appliance is either 

faulty or the appliances required power is greater than 

the generators output, check the appliances wattage 

requirements.

12V DC OUTLET

Your generator is equipped with a DC output circuit 

breaker. This circuit breaker will “pop” out if the attached 

appliance is either faulty or the appliances required 

power need is greater than the generators DC power 

output.
To reset the circuit breaker and restart the power supply;
1.  Remove the appliance.
2.  Stop the generator, see page 12.
3.  Wait 2 minutes.

4. Push the circuit breaker back in, it should stay in. If 

not the circuit breaker is still over heated, allow to 

cool down for another 2 minutes before trying again 

to push it in.

5.  Start generator.
6.  Re - attach the appliance.
7. If the circuit breaker “pop’s” out again and the power 

stops then the attached appliance is either faulty 

or the appliances required power is greater than 

the generators output, check the appliances power 

requirements.

LOW OIL LIGHT

If the oil level in the motor sump drops to a dangerously 

low level then the generator will automatically stop. 
If the oil level in the motor sump is dangerously low, then 

the generator will not start, however the low oil light will 

flicker only when the recoil starter is pulled.
If your generator will not start always check the oil level 

first.
To add oil or check the oil level, refer page 10.

Summary of Contents for 2200W

Page 1: ...2200W DIGITAL INVERTER Instruction Manual 03708 02 18 For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876 PLU 553024 ...

Page 2: ...ces CONTENTS Section Page Contents 2 Suggested Applications 2 Introduction 3 Warranty 3 4 General Safety Instructions 5 6 Specific Safety Instructions 7 Electrical Information 8 Fuel Oil Information 8 Components Controls 9 Operating Instructions 10 15 Maintenance Chart 16 Maintenance 17 18 Fault Chart 19 20 Service Log 21 Specification 22 Parts Diagram 23 Please take note of serial number and writ...

Page 3: ...th parts and components of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished parts may be used to repair the products What is covered Manufacturing fault or defect How to claim under this warranty Call customer service phone number ...

Page 4: ...composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished parts may be used to repair the products Damage caused by third party accessories is not covered under this warranty Damage caused to attached equipment or third party accessories will not be covered under th...

Page 5: ...ith the fuel tank empty SELECT A GENERATOR WITH A SUFFICIENT RATING Select the right generator for the job Do not use a generator to do a job for which it was not designed Do not force a small generator to do the job of a heavy duty generator Any damage caused by overloading will void the warranty Do not use generators for purposes not intended PROTECT POWER LEADS FROM DAMAGE Always disconnect pow...

Page 6: ...any other part of the generator that is damaged should be properly repaired or replaced by an authorised service facility unless otherwise indicated in this instruction manual Any switch that does not operate correctly must be replaced by an authorised service facility DO NOT use the generator if the ON OFF motor switch does not turn the generator ON and OFF PERSONAL SAFETY Clothing Do not wear lo...

Page 7: ...p before starting the generator Never operate or store the generator on its side ALWAYS operate or store in an upright manner on firm solid ground Your generator is factory set NEVER attempt to speed it up as this could endanger the user and damage the generator and or attached appliances Never operate the generator in damp wet or flooded conditions Before plugging appliances into the generator al...

Page 8: ...tainer to store your unleaded petrol ULP in before decanting into the fuel tank If contaminated dirty or old stale fuel is used any damage caused will not be covered under warranty OIL CHECK DAILY ONLY USE 4 STROKE MOTOR OIL To operate this generator requires oil in the sump not supplied If the generator does not have the correct level of oil in the sump it will not run see note below Oil capacity...

Page 9: ...ash 2 times high temperature protection C Interval Flash 3 times overload protection too many loads D Interval Flash 4 times short circuit protection The output power will be cut off should the generator is experiencing any of the faults that are mentioned above Stop the engine to fix the issue before restarting the engine 4 Earth bolt point for earth lead 5 5V USB socket 6 AC socket 7 Air filter ...

Page 10: ... 1 Ensure that engine is OFF when filling oil 2 Use oil as detailed on page 8 SAE 30W or SAE 15W 40 4 stroke motor oil 3 Ensure generator is level when filling with oil DO NOT TIP USE A FUNNEL NOT SUPPLIED 4 Remove oil filler cap Pic 2 5 Only fill oil to the top of the thread Pic 3 6 Ensure that the oil filler cap is screwed on tightly before attempting to start the generator WARNING Over filling ...

Page 11: ... or power leads attached 1 Ensure the Earth stake and wire are attached Pic 5 2 Turn the fuel tap ON Pic 6 3 Turn choke to CLOSED START by sliding the choke lever to the left Pic 7 4 Turn the engine switch to ON Pic 8 5 Hold down the generator firmly with one hand on the frame then pull the recoil starter slowly until engaged then pull briskly Pic 9 This step may need to be repeated until generato...

Page 12: ...ATOR Warning Never stop your generator with electrical appliances or power leads attached Always remove power leads and appliances before stopping your generator WARNING In case of emergency the easiest way to stop the generator is to directly turn engine switch to OFF position Avoid doing so in non emergency circumstances as it carries the risk of damaging the generator 1 Ensure all power leads a...

Page 13: ...fore using the generator 2 Lift the flap and plug your appliance into the outlet socket on the face plate 3 Turn the appliance on and use as per the manufacturers manual 4 When finished turn your appliance off 5 Disconnect appliance from the generator and the flap should close automatically NEVER leave any appliances plugged into your generator always disconnect when appliance is not in use Sugges...

Page 14: ...eater than the generators output check the appliances wattage requirements 12V DC OUTLET Your generator is equipped with a DC output circuit breaker This circuit breaker will pop out if the attached appliance is either faulty or the appliances required power need is greater than the generators DC power output To reset the circuit breaker and restart the power supply 1 Remove the appliance 2 Stop t...

Page 15: ...2 Position an approved fuel container under the carburetor drain screw to catch fuel loosen the screw Pic 14 Allow fuel to drain completely into container 3 Retighten drain screw 4 After draining the fuel tank and carburetor start the engine and allow it to run until the unit runs out of fuel Consult hazardous waste management guidelines in your area for the proper way to dispose of fuel When prep...

Page 16: ...ne Check fuel hose for cracks or damage Replace if required Exhaust system Check for leakage Tighten or replace gasket if required Check exhaust screen Clean and replace if required Carburetor Check choke operation Fittings Fastenings Check all fittings and fixtures and tighten if required SERVICE Now that you have purchased your tool should a need ever exist of repair or service simply contact yo...

Page 17: ...RK PLUG MAINTENANCE The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check 1 Remove the spark plug cap Pic 17 2 Clean any dirt from around base of spark plug 3 Remove spark plug using wrench provided Pic 18 4 Inspect spark plug for damage and clean with a wire brush before reinstalling If insulator is cracked or chipped spark plug should be ...

Page 18: ...sed and or your operating conditions the exhaust port and muffler may become blocked with carbon deposits If you notice a power loss with your petrol powered tool you may need to remove these deposits to restore performance We highly recommend that only qualified service technicians perform this service CLEANING THE FUEL TANK FILTER 1 Remove fuel cap and filter 2 Clean the filter replace if broken...

Page 19: ...chamber supplied with fuel Poor spark Pull rope sharply Clean tank Clean fuel line with dealers advice Fill with correct fuel See page 8 Open tap Spark plug dirty with carbon or wet with fuel Remove carbon or dry spark plug Damaged spark plug Replace spark plug Faulty magneto Consult dealer Improper adjustment of carburetor Good spark Insufficient pulling speed for starting rope Pull rope sharply ...

Page 20: ...and repair Check and repair Generator problem Indicator light OFF No AC output Output power too high or low Engine RPM set too high or low No load speed set to 3000rpm Loose d n a e t a c o L t n e n o p m o c tighten Internal generator problem Consult dealer REPAIRS Repairs to your generator should only be carried out by an authorised service agent Call Smart Marketing Group for your closest cent...

Page 21: ...ne filter Fitting fastenings Authorised Service Agent Name or Company Stamp Technician Date This service is to be completed within 200 hours or 9 months of purchase which ever comes first Replace Check Adjust Engine oil Exhaust System Air filter Carburetor Fuel line filter Starting system Spark plug Authorised Service Agent Name or Company Stamp Technician Date This service is to be completed with...

Page 22: ... motor oil SAE 30W or SAE 15W 40 Fuel tank capacity 7L Fuel type Unleaded 91 Petrol no ethanol Spark plug F7RTC Rated voltage 240V AC 50Hz Rated output 2000W Maximum output 2200W Rated current 8 3A Power factor 1 0 12V DC output 5A USB output 5V Max 2 1A Maximum temperature altitude 40ºC 1000m Spark arrestor Yes Inverter Yes Noise 68db A at 7m Nett weight 19 kg ...

Page 23: ...23 ...

Page 24: ...d packaged for SRGS PTY LTD ABN 23 113 230 050 751 Gympie Road Lawnton Queensland 4501 Australia Output LED Light 7L Fuel tank Twin USB outlet 240V AC 50Hz Outlet socket 12V DC Cigarette lighter socket Generator ON OFF switch Recoil starter ...

Reviews: