TH2683A Operation Manual
Ver.1.3
18
It is used for setting the PICKOUT BEEP as OFF.
Touch the corresponding key in soft key zone to select the relevant function.
NOTE:
1.
The BIN ONE enjoys the top priority in the three bins, followed by BIN TWO and BIN
THREE. BIN TWO and BIN THREE will not compare when BIN ONE passes, and so on, the
test fails when all three bins fail.
2.
The pickout results will be displayed on the main display interface when the PICK
FUNC is set as ON. When one of the three bins passes, the main display interface will light
up the green light and indicates BIN1, BIN2 and BIN3. When all three bins fail, the main
display interface will light up the red light and indicates FAIL.
3.3.5
Steps for BIN Disp
Touch the corresponding zone. The following items will be displayed in the soft key zone.
ON
It is used for setting the BIN Disp as ON.
OFF
It is used for setting the BIN Disp as OFF.
Touch the corresponding key in soft key zone to select the relevant function.
3.3.6
Steps for PICK LIVA
Touch the corresponding zone. The following items will be displayed in the soft key zone.
ON
It is used for setting the PICK LIVA as ON.
OFF
It is used for setting the PICK LIVA as OFF.
Touch the corresponding key in soft key zone to select the relevant function.
NOTE:
1.
When the PICK LIVA is set as OFF, if the PICK ITEM is set as RESIS, the upper limit
value of BIN1, BIN2 and BIN3 will be set as infinitely great and become unchangeable and
drop out of compare, namely, the pickout changes from interval pickout to single
‐
point
pickout; if the PICK ITEM is set as CURR, the lower limit value of BIN1, BIN2 and BIN3 will
be set as 0 and become unchangeable and drop out of compare, namely, the pickout also
changes from interval pickout to single
‐
point pickout.
2.
When the PICK LIVA is set as ON, whether the PICK ITEM is set as RESIS or CURR, set
the limit value according to the above steps.
3.
Whether the PICK LIVA is set as ON or OFF, the priority level of BIN1, BIN2 and BIN3
keeps invariant.