66
User Manual
(2) Video channel property
Description: Through the Video Surveillance to achieve the DVR active connection platform client (when system abnormal restart or power-off restart). The associated configuration
steps are as follows:
Installed the “Video Surveillance System” in the PC terminal, and then log on platform client, click on the “Configuration” - > “Device Management” - > “Add Device”, put the device
name in this page; Device type selection “Initiative”, video channel number, the number of alarm input, alarm output etc., click “OK” to finish device added. After that, click “Modify”
the icon, obtain device registration code (license), like the picture as below.
Through the “Server” from DVR - > “Video channel property”, and then click “Load” into the configuration interface, as shown on the bottom right. Fill out the IP In this page (IP
address is the same as the PC platform server address). Port (Default: 8000, the streaming media forwarding ports, platform client login page “port” or “Configuration” from Client -
> “System management” page view), Register ID (device registration code), Click “Open” and save.
Exit “Video channel property” interface, can see the status display “connected” when enter again and can operate to the device, as well as ordinary passive connection mode of
operation.
If the connection fails, it will display the “Network Disconnected”. Device connection platform client successfully, can operate and configure the device as normal connection way
by Client software.
Video Channel Property