Message Code 23 & 123 – PROX CYCLED TWICE FAULT
This fault will not occur if Hard Cams are chosen on the position
Control screen.
When a resolver or an Encoder is the primary means of checking
motion, the PP150 has the capability of setting any window in the
stroke for the prox check switch to cycle. Once this window has been
set, the prox should come on and off inside this window. There also is
programming used to debounce any false readings that may occur
during normal cycling of the prox switch. Once the prox switch angle
is verified, the prox window is computed and automatically applied.
This window allows the prox switch to cycle as many times as it wants
in order to alleviate nuisance faults. If the prox is still cycling
outside of this window, this fault will occur. Press the PP150 reset
button to reset this fault.
Message Code 24 & 124 – NO PROX IN WINDOW FAULT
This fault will not occur if Hard Cams are chosen on the position
Control screen.
This fault will occur when the prox check has failed to cycle inside
the user defined window. Make sure that the prox is mounted
correctly, and that the window is set to capture when the prox cycles.
Change accordingly, and press the PP150 reset button to reset this
fault.
Message Code 25 & 125 – TOP STOP OVERRUN FAULT
A Top stop is defined as a stopping point in the top zone of the stroke.
Top Zone is defined as the degrees between Tcam off and Bcam on.
Knowing this information, the press must stop between Tcam off and
Bcam on in order to top stop. If the press stops after Bcam has
turned on, this is considered a top stop overrun and will result in
this fault. This fault will only occur if a top stop has been initiated,
and the press fails to stop before Bcam on. Make sure the Tcam off
angle is correct, the condition of the brake is in good condition,
counter balance pressure is correct, and press the PP150 reset
button to reset the fault.
Message Code 26 & 126 – BRAKE MONITOR FAULT
This fault will occur when the brake monitor stopping time has
exceeded the user defined set point. Before resetting the fault,
investigate the cause of the excessive stopping time and take
corrective action. Press the PP150 reset button to reset the fault.
Message Code 27 & 127 – COUNTER BAL AIR PRESSURE FAULT
The PP150 is constantly checking to make sure the system has a good
signal from the counter balance air pressure switch. Make sure the
counter balance air pressure switch is set correctly in order for the
PP150 to accurately advise of incorrect pressure. Check the
pressure switch, and press the PP150 reset button to reset the
fault.
Summary of Contents for Press Pilot 150
Page 2: ......
Page 4: ..._ Doc 16302 Press Pilot 150 Manual Page 2 ...
Page 54: ..._ Doc 16302 Press Pilot 150 Manual Page 52 ...
Page 55: ..._ Doc 16302 Press Pilot 150 Manual Page 53 ...
Page 67: ..._ Input Word 3 Figure 11 4 Doc 16302 Press Pilot 150 Manual Page 65 Input Word 2 Figure 11 3 ...
Page 68: ..._ Doc 16302 Press Pilot 150 Manual Page 66 Input Word 4 Figure 11 5 Input Word 15 Figure 11 6 ...
Page 69: ..._ Doc 16302 Press Pilot 150 Manual Page 67 Input Words 4 40 Figure 11 7 ...
Page 71: ..._ Doc 16302 Press Pilot 150 Manual Page 69 Output Word 1 Figure 11 10 ...
Page 73: ..._ Doc 16302 Press Pilot 150 Manual Page 71 ...
Page 83: ..._ Doc 16302 Press Pilot 150 Manual Page 81 Figure 16 5 Figure 16 6 ...
Page 86: ......
Page 87: ...MAIN RESOLVER ENCODER CAMS ...
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 115: ...Doc 16302 Press Pilot 150 Manual Page118 Figure 8 Figure 9 ...