8
PREPARATION BEFORE OPERATION
1.
Selection of a compressor and method of draining the system.
・
Method of selection; (Please refer to the specification chart to see the air consumption
for each model.)
( Air Consumption
×
10 )
×
No. of units
≦
Horse Power of Compressor
・
Method of Draining the system;
If water or oil accumulates inside the system, this will result in rust and eventually cause
damage or a breakdown. Before using the equipment, loosening the drain plug which is
located at the bottom of the tank on the compressor and drain the accumulated
water/moisture or oil. Make sure clean dry air is used. (For details and instructions refer
to the Compressor Instruction manual.)
2.
Piping
△
!
CAUTION;
Install an air filter, regulator and line oiler near the air winch.
Size; 1B(25mm) is recommended. (To assure performance)
△
!
CAUTION;
Install a drain in the lowest area in your piping and drain the system
regularly.
If the air contains a lot of moisture or water, it may cause the silencer on the Air
Winch to freeze. Also it may lead to a breakdown due to rust developing inside
the Air Winch.
Air & Allied Sales (Pacific) Pty Ltd
www.air-allied.com.au