![Tohnichi TDT3-G Operating Instruction Download Page 14](http://html1.mh-extra.com/html/tohnichi/tdt3-g/tdt3-g_operating-instruction_1124791014.webp)
13
n
D
IG
IT
A
L
T
O
R
Q
U
E
S
C
R
E
W
D
R
IV
E
R
T
E
S
T
E
R
M
O
D
E
L
T
D
T
3
-G
Refer to below table for various settings, functions and operation.
6-1. Settings
• Registration of Upper/Lower limit value
6
Various Settings
Setting Subject
Main Display
Default
Select TDT60CN3 (TDT600CN3)
1
Select subject to set
- -
torq-S
PArA-S
2
Measuring unit
Unit
cN·m
4 different measurement unit by
t
mark
3
Upper limit value (A)
HI
SEt-A
00.000 (000.00)
00.000-60.000 (000.00-600.00)
4
Lower limit value (A)
Lo
SEt-A
00.000 (000.00)
00.000-60.000 (000.00-600.00)
5
Upper limit value (B)
HI
SEt-b
00.000 (000.00)
00.000-60.000 (000.00-600.00)
6
Lower limit value (B)
Lo
SEt-b
00.000 (000.00)
00.000-60.000 (000.00-600.00)
23
Upper limit value (J)
HI
SEt-J
00.000 (000.00)
00.000-60.000 (000.00-600.00)
24
Lower limit value (J)
Lo
SEt-J
00.000 (000.00)
00.000-60.000 (000.00-600.00)
* When memory mode is set to “99”, upper/lower limit value will be 4 digits at max.
Upper
Left
Screen
Lower
Left
Screen
• Parameter settings
Setting Subject
Main Display
Default
Selection
1
Auto memory/Reset
Ar
0.0
0.1/0.2/0.3/0.4/0.5/1.0/2.0/3.0/4.0/5.0
2
Key operation sound
bU
on
oFF
3
External output
doUt
PC
Prn
4
Baud rate
bPS
2400
4800/9600/19200
5
Data length
LngtH
7bit
8bit
6
Parity
PArty
nonE
odd/EVEn
7
Memory mode
dCnt
1000
99
8
Default setting
dFLt
dFLt-n
dFLt-y
Upper
Left
Screen
Lower
Left
Screen