TOELLNER TOE 9261 Instruction Manual Download Page 6

 

Section 2 

– Operation 

 

 

TOELLNER Electronic Instrumente GmbH 

2. 

Operation 

2.1 

Startup 

Warning

 

Safe operation of these devices presumes that they have been placed in service properly 
by qualified personnel in compliance with the warnings in this manual. 

In particular the general installation and safety regulations (e.g. DIN/EN and VDE) must be 
observed. Non-observance may result in death, serious personal injury or major damage 
to equipment. 

These devices meet Protection Class I (protective earth connection) according to DIN 
EN61010-1. Before powering up, be sure that the mains voltage agrees with the 
permissible operating voltage of the device (

 4.1 Technical data TOE 9261 and the 

rating plate). Except in areas with special protection measures, the mains plug must only 
be inserted in a socket having a PE contact. The protection effect must never be defeated 
through use of an extension cable not having a protective earth. The mains plug must be 
inserted in the socket before the device is turned on and the measuring and control circuits 
connected. Any interruption in the protective earth inside or outside the unit or removal of 
the protective earth connection may result in a hazardous condition for the device. No 
intentional interruption of the protective earth connection is permitted. Observe local 
regulations for earthing. 

Ensure that only fuses of the specified type and specified current are used as 
replacements (

 4.1 Technical data TOE 9261 and the rating plate). The use of repaired 

fuses or short circuiting the fuse holder is not permitted. 

If it is apparent that non-hazardous operation is no longer possible, the devices must be 
taken out of service and secured against unintended operation. 

 

2.1.1 

Installation and ventilation 

There are no problems associated with installation of these devices. 

The devices include a thermostatically controlled fan which brings in air from the sides and 
below and blows it out to the rear. Provide sufficient ventilation distance so that the rear fan 
can work effectively. Otherwise it can happen that under high load conditions the unit will 
heat up to a point where it is automatically shut off (

 2.6.4 Excessive temperature 

protection). 

Series 

TOE 9261

 devices are designed so that they can be used either as tabletop units or 

in 19" rack systems. Appropriate adapters for 19" rack use are available as an option. 
 

2.1.2 

Preparations 

OFF

ON

 

After connecting the mains supply and pressing the 

 POWER 

 switch the device is ready. This 

is indicated by the green power LED above the mains switch. 

 

Summary of Contents for TOE 9261

Page 1: ...n Manual Electronic Switch TOE 9261 9261E Manual Rev05 doc R TOELLNER ELECTRONIC INSTRUMENTE GMBH Gahlenfeldstra e 31 58313 Herdecke Germany 49 0 23 30 97 91 91 Fax 49 0 23 30 97 91 97 E Mail info toe...

Page 2: ...switching a ground line minus 10 2 4 6 Connection of the control signal 10 2 4 7 Control of switching paths and operation of the consumer 10 2 4 8 Display of the switching states 11 2 4 9 Use of the b...

Page 3: ...ual When operating electronic equipment certain parts in these devices are necessarily under dangerous voltage Non observance of the warnings may therefore result in severe bodily injury or damage to...

Page 4: ...a feeding source to the connected consumer The branch path in this case is arranged parallel to the consumer and can be optionally connected via a DIL switch It serves as needed to selectively dischar...

Page 5: ...h TTL CMOS 5 V and LVCMOS 3 3 V Permissible switching frequency DC up to 100 kHz Protected against overcurrent short circuit excessive temperature excessive switching frequency 1 2 Model overview Seri...

Page 6: ...result in a hazardous condition for the device No intentional interruption of the protective earth connection is permitted Observe local regulations for earthing Ensure that only fuses of the specifi...

Page 7: ...or rear CONTROL input 3 Front panel BNC input CONTROL for controlling the switching state both for the power switch and the signal line switches 2 4 7 Control of switching paths and operation of the c...

Page 8: ...e illuminated 12 Red OVL LED Overload Comes on when a shutdown has occurred due to one of the following fault conditions Max switching frequency of 100 kHz on the control input has been exceeded Overc...

Page 9: ...f the consumer for switching a ground line the input voltage should be connected to this socket and to the Minus socket otherwise to the left hand Plus socket and the Minus socket The applied voltage...

Page 10: ...also the above mentioned improper load current flow via the 0 1 resistor is automatically locked Warning In the described switch configuration the positive supply line from the voltage source to the c...

Page 11: ...PULL UP ON to ON the internally evaluated level changes to High resulting in switching path S1 becoming conductive and switching path S2 non conductive In the configuration for switching the positive...

Page 12: ...e rise and fall times are lengthened High buffer capacities with low series resistance values ESR can also result in triggering of the overcurrent fuse Warning Feedback from the buffered load side to...

Page 13: ...ged by excessive ripple current loads 2 5 Operation of the signal line switches 2 5 1 Connection To switch signal lines they are routed through the bidirectional switches S3 S6 They are connected usin...

Page 14: ...reset is accomplished by turning the unit off and on using the mains switch The cause of the overcurrent or short circuit must be identified and eliminated 2 6 2 Input overcurrent protection The input...

Page 15: ...n responds to excessive component temperatures in the unit This protection is provided in two stages For continuous operation at high voltage high current and high switching frequency the fan speed is...

Page 16: ...to the 19 adapter piece 1 Insert this unit in replacement for the fill strip and screw it on to the front panel using the hexagon socket screws 6 4 For the other side attach the adapter bracket 3 to...

Page 17: ...ice Pull the four fill strips 5 from the side 3 For the outer faces of the devices attach a handle 4 to a 19 adapter piece 1 each using the countersunk screws 7 Insert these units in replacement for t...

Page 18: ...ower switch switching times Rise time tr with reference resistor 1 With connected input buffer capacitor Without buffer capacitor input cable 0 50 m twisted Without buffer capacitor input cable 1 20 m...

Page 19: ...Increase in fan speed Stage 2 Switching off of switching paths display OVL Switching off and on again using mains switch following appropriate cooling period Power switch is not reverse polarity prot...

Page 20: ...luded accessories 1 mains cable 2 terminal blocks for signal line switches 1 Instruction Manual Optional accessories 0 50 m connection cable with 1 safety socket red TOE 9260 22 0 50 m connection cabl...

Page 21: ...t 8 Selectable base load 10 k or 100 k with green indication LED 9 Power switch branch path incl red indication LED 10 0 series resistor for branch path with green indication LED 11 0 1 series resisto...

Reviews: