Technical data 

Note 

The technical data are based on a warm-up time of at least 30 minutes under constant 
conditions and a reference temperature of 23°C ±1°C. 

 
 

4.1 

Technical data TOE 9261 

 

Model

 

TOE 9261-50

 

TOE 9261-100

 

Input voltage

 

 

 

Power switch 

0 - 60 V

 

0 - 60 V

 

Signal line switches 

0 - 60 V

 

0 - 60 V

 

Load current

 

 

 

Power switch, longitudinal path 

 

 

Continuous current 

0 - 50 A 

 

0 - 100 A 

 

Peak current 

300 A 

300 A 

Power switch, branch path

 

 

 

Continuous current 

0 - 50 A 

 

0 - 100 A 

 

Peak current 

300 A 

300 A 

Signal line switches 

0 - 2 A

 

0 - 2 A

 

Voltage drop 

 

 

Power switch, longitudinal path 

< 0.2 V

 at 50 A

 

< 0.3 V

 at 100 A

 

Power switch, branch path 

< 0.2 V

 at 50 A

 

< 0.3 V

 at 100 A

 

Signal line switches 

< 0.4 V

 at 2 A

 

Switching frequency f

MAX

 

100 kHz

 

Power switch switching times 

 

Rise time t

r

 with reference resistor 1 

Ω 

With connected input buffer capacitor 
Without buffer capacitor, input cable 0.50 m twisted 
Without buffer capacitor, input cable 1.20 m twisted 
 

Rise time t

r

 with reference resistor 100 

Ω 

With or without input buffer capacitor, 
input cable 

≤ 

1.2 m twisted 

 

 

< 0.5 µs 
< 1.2 µs 
< 2.0 µs 

 
 
 

< 0.5 µs 

Fall time t

f

 with reference resistor 1 

Ω or 100 Ω 

With or without input buffer capacitor, 
input cable ≤ 1.2 m twisted 

 
 

< 0.5 µs

 

PWM operation of power switch 

 

Operating duration 

With load current 

 50 A 

With load current > 50 

A … 

 100 A 

(automatic switch-off at

 

overload) 

 

No limitation 

-- 

 

No limitation 

Typ. 5 min 

Switching frequency 

With duty cycle 50 %, input cable 0.50 m twisted 

With input voltage 14 V 
With input voltage 40 V 

 
 

DC up to 100 kHz 

DC up to typ. 20 kHz 

(

 2.4.11 PWM operation of a consumer)

 

Switching times for signal line switches

 

 

Rise time t

r

 

With 1 

Ω load, V

IN

 = 2 V 

With 1 

kΩ load 

 

< 2.5 µs 
< 0.1 µs 

Fall time t

f

 

With 1 

Ω load, V

IN

 = 2 V 

With 1 

kΩ load 

 

< 1.5 µs 
< 6.5 µs 

 

Summary of Contents for TOE 9261

Page 1: ...n Manual Electronic Switch TOE 9261 9261E Manual Rev05 doc R TOELLNER ELECTRONIC INSTRUMENTE GMBH Gahlenfeldstra e 31 58313 Herdecke Germany 49 0 23 30 97 91 91 Fax 49 0 23 30 97 91 97 E Mail info toe...

Page 2: ...switching a ground line minus 10 2 4 6 Connection of the control signal 10 2 4 7 Control of switching paths and operation of the consumer 10 2 4 8 Display of the switching states 11 2 4 9 Use of the b...

Page 3: ...ual When operating electronic equipment certain parts in these devices are necessarily under dangerous voltage Non observance of the warnings may therefore result in severe bodily injury or damage to...

Page 4: ...a feeding source to the connected consumer The branch path in this case is arranged parallel to the consumer and can be optionally connected via a DIL switch It serves as needed to selectively dischar...

Page 5: ...h TTL CMOS 5 V and LVCMOS 3 3 V Permissible switching frequency DC up to 100 kHz Protected against overcurrent short circuit excessive temperature excessive switching frequency 1 2 Model overview Seri...

Page 6: ...result in a hazardous condition for the device No intentional interruption of the protective earth connection is permitted Observe local regulations for earthing Ensure that only fuses of the specifi...

Page 7: ...or rear CONTROL input 3 Front panel BNC input CONTROL for controlling the switching state both for the power switch and the signal line switches 2 4 7 Control of switching paths and operation of the c...

Page 8: ...e illuminated 12 Red OVL LED Overload Comes on when a shutdown has occurred due to one of the following fault conditions Max switching frequency of 100 kHz on the control input has been exceeded Overc...

Page 9: ...f the consumer for switching a ground line the input voltage should be connected to this socket and to the Minus socket otherwise to the left hand Plus socket and the Minus socket The applied voltage...

Page 10: ...also the above mentioned improper load current flow via the 0 1 resistor is automatically locked Warning In the described switch configuration the positive supply line from the voltage source to the c...

Page 11: ...PULL UP ON to ON the internally evaluated level changes to High resulting in switching path S1 becoming conductive and switching path S2 non conductive In the configuration for switching the positive...

Page 12: ...e rise and fall times are lengthened High buffer capacities with low series resistance values ESR can also result in triggering of the overcurrent fuse Warning Feedback from the buffered load side to...

Page 13: ...ged by excessive ripple current loads 2 5 Operation of the signal line switches 2 5 1 Connection To switch signal lines they are routed through the bidirectional switches S3 S6 They are connected usin...

Page 14: ...reset is accomplished by turning the unit off and on using the mains switch The cause of the overcurrent or short circuit must be identified and eliminated 2 6 2 Input overcurrent protection The input...

Page 15: ...n responds to excessive component temperatures in the unit This protection is provided in two stages For continuous operation at high voltage high current and high switching frequency the fan speed is...

Page 16: ...to the 19 adapter piece 1 Insert this unit in replacement for the fill strip and screw it on to the front panel using the hexagon socket screws 6 4 For the other side attach the adapter bracket 3 to...

Page 17: ...ice Pull the four fill strips 5 from the side 3 For the outer faces of the devices attach a handle 4 to a 19 adapter piece 1 each using the countersunk screws 7 Insert these units in replacement for t...

Page 18: ...ower switch switching times Rise time tr with reference resistor 1 With connected input buffer capacitor Without buffer capacitor input cable 0 50 m twisted Without buffer capacitor input cable 1 20 m...

Page 19: ...Increase in fan speed Stage 2 Switching off of switching paths display OVL Switching off and on again using mains switch following appropriate cooling period Power switch is not reverse polarity prot...

Page 20: ...luded accessories 1 mains cable 2 terminal blocks for signal line switches 1 Instruction Manual Optional accessories 0 50 m connection cable with 1 safety socket red TOE 9260 22 0 50 m connection cabl...

Page 21: ...t 8 Selectable base load 10 k or 100 k with green indication LED 9 Power switch branch path incl red indication LED 10 0 series resistor for branch path with green indication LED 11 0 1 series resisto...

Reviews: