TOELLNER TOE 9261 Instruction Manual Download Page 5

 

Section 1 

– Introduction 

 

 

TOELLNER Electronic Instrumente GmbH 

1.1.2 

Overview of features 

Basic functions 

-  Electronic power switch consisting of longitudinal and branch path, both paths 

unidirectional for specified current flow direction 

-  Branch path selectable inactive, active without series resistor or active with series 

resistor 0.1 

Ω 

-  High-impedance loads of 10 

kΩ or 100 kΩ can be continually applied 

-  Applicability

 

of branch path for switching ground lines or return lines 

-  Capacitive buffering of input can be applied 
-  Four electronic bidirectional signal line switches 
-  BNC control inputs at front and rear 
-  Control signal can be internally inverted 
-  Pull-up resistor can be connected to the control inputs 
-  Control inputs compatible with TTL, CMOS 5 V, and LVCMOS 3.3 V 
-  Permissible switching frequency DC up to 100 kHz 
-  Protected against overcurrent / short-circuit, excessive temperature, excessive switching 

frequency 

 

1.2 

Model overview 

Series 

TOE 9261

 devices are available in models for various rated currents. The rated 

current of the power switch is indicated by a hyphenated number added to the basic part 
number. 

The rated currents for the signal line switches as well as the rated voltages are shown in the 
following table. 
 
Series 

TOE 9261

 electronic switches 

 

Model 

Power switch 

Signal line switches 

Current 

Voltage 

Current 

Voltage 

TOE 9261-50 

0 - 50 A 

0 - 60 V 

0 - 2 A 

0 - 60 V 

TOE 9261-100 

0 - 100 A 

0 - 60 V 

0 - 2 A 

0 - 60 V 

 

1.3 

Schematic diagram for TOE 9261 

S1

S2

0.1 Ω

OUT

IN

+

+

Control

Logic

&

Driver

S3

S4

S5

S6

 

 

S1: 

Unidirectional electronic 
power switch, 
longitudinal path 

S2: 

Unidirectional electronic 
power switch, branch 
path 

S3…S6:  Four electronic 

bidirectional signal line 
switches 

 

Summary of Contents for TOE 9261

Page 1: ...n Manual Electronic Switch TOE 9261 9261E Manual Rev05 doc R TOELLNER ELECTRONIC INSTRUMENTE GMBH Gahlenfeldstra e 31 58313 Herdecke Germany 49 0 23 30 97 91 91 Fax 49 0 23 30 97 91 97 E Mail info toe...

Page 2: ...switching a ground line minus 10 2 4 6 Connection of the control signal 10 2 4 7 Control of switching paths and operation of the consumer 10 2 4 8 Display of the switching states 11 2 4 9 Use of the b...

Page 3: ...ual When operating electronic equipment certain parts in these devices are necessarily under dangerous voltage Non observance of the warnings may therefore result in severe bodily injury or damage to...

Page 4: ...a feeding source to the connected consumer The branch path in this case is arranged parallel to the consumer and can be optionally connected via a DIL switch It serves as needed to selectively dischar...

Page 5: ...h TTL CMOS 5 V and LVCMOS 3 3 V Permissible switching frequency DC up to 100 kHz Protected against overcurrent short circuit excessive temperature excessive switching frequency 1 2 Model overview Seri...

Page 6: ...result in a hazardous condition for the device No intentional interruption of the protective earth connection is permitted Observe local regulations for earthing Ensure that only fuses of the specifi...

Page 7: ...or rear CONTROL input 3 Front panel BNC input CONTROL for controlling the switching state both for the power switch and the signal line switches 2 4 7 Control of switching paths and operation of the c...

Page 8: ...e illuminated 12 Red OVL LED Overload Comes on when a shutdown has occurred due to one of the following fault conditions Max switching frequency of 100 kHz on the control input has been exceeded Overc...

Page 9: ...f the consumer for switching a ground line the input voltage should be connected to this socket and to the Minus socket otherwise to the left hand Plus socket and the Minus socket The applied voltage...

Page 10: ...also the above mentioned improper load current flow via the 0 1 resistor is automatically locked Warning In the described switch configuration the positive supply line from the voltage source to the c...

Page 11: ...PULL UP ON to ON the internally evaluated level changes to High resulting in switching path S1 becoming conductive and switching path S2 non conductive In the configuration for switching the positive...

Page 12: ...e rise and fall times are lengthened High buffer capacities with low series resistance values ESR can also result in triggering of the overcurrent fuse Warning Feedback from the buffered load side to...

Page 13: ...ged by excessive ripple current loads 2 5 Operation of the signal line switches 2 5 1 Connection To switch signal lines they are routed through the bidirectional switches S3 S6 They are connected usin...

Page 14: ...reset is accomplished by turning the unit off and on using the mains switch The cause of the overcurrent or short circuit must be identified and eliminated 2 6 2 Input overcurrent protection The input...

Page 15: ...n responds to excessive component temperatures in the unit This protection is provided in two stages For continuous operation at high voltage high current and high switching frequency the fan speed is...

Page 16: ...to the 19 adapter piece 1 Insert this unit in replacement for the fill strip and screw it on to the front panel using the hexagon socket screws 6 4 For the other side attach the adapter bracket 3 to...

Page 17: ...ice Pull the four fill strips 5 from the side 3 For the outer faces of the devices attach a handle 4 to a 19 adapter piece 1 each using the countersunk screws 7 Insert these units in replacement for t...

Page 18: ...ower switch switching times Rise time tr with reference resistor 1 With connected input buffer capacitor Without buffer capacitor input cable 0 50 m twisted Without buffer capacitor input cable 1 20 m...

Page 19: ...Increase in fan speed Stage 2 Switching off of switching paths display OVL Switching off and on again using mains switch following appropriate cooling period Power switch is not reverse polarity prot...

Page 20: ...luded accessories 1 mains cable 2 terminal blocks for signal line switches 1 Instruction Manual Optional accessories 0 50 m connection cable with 1 safety socket red TOE 9260 22 0 50 m connection cabl...

Page 21: ...t 8 Selectable base load 10 k or 100 k with green indication LED 9 Power switch branch path incl red indication LED 10 0 series resistor for branch path with green indication LED 11 0 1 series resisto...

Reviews: