22
5.4.2. DS LINK terminal connections
Connect the DS LINK terminal of the VX-3150DS to the DS Link connectors of the VX-3004F, VX-3008F, or
VX-3016F. The figure below shows a connection example when the VX-3150DS units are connected to the VX-
3004F. This connection also applies to the VX-3008F and VX-3016F.
Insulation sleeve
Contact section
Insulation sleeve
Contact section
a
l
2
a
1
a
2
l
1
l
2
l
1
b
b
[Cable termination]
When connecting 2 cables or a shielded cable to a single terminal, use a ferrule terminal with an insulation
sleeve to crimp the cables because such cable conductors could become loose.
Recommended ferrule terminals for signal cables
(made by DINKLE ENTERPRISE)
Unit: mm
Model Number
a
b
l
1
l
2
1
DN00308D
1.9
0.8
12
8
2
DN00508D
2.6
1
14
8
Recommended ferrule terminals for power supply cables
(made by DINKLE ENTERPRISE)
Unit: mm
Model Number
a
a
1
a
2
b
l
1
l
2
3
DN01508D
3.5
-
-
1.7
14
8
4
DN01508B
-
6.6
3.6
2.3
16
8
Crimping tool: DNT01-2206B (made by DINKLE ENTERPRISE)
TEMPER
ATURE
SENSOR
24V(16-25V)
PO
WER OUT
MAX 0.3A
IN
OUT
DS LINK
DS LINK
IN
OUT
VX-3150DS
VX-3004F
230 V AC
220 V AC
50/60 Hz
Cat. 5 STP