6. Setting Mode
6.1. How to enter
To enter the function settings, do either of the following.
A) When the display is off, press ON/OFF key while pressing the TARE key.
B) When in the weighing mode, press and hold the TARE key for more 2 seconds.
Step 1. At this time,
“
F-01
” is shown on the display after “
SET
” message.
Step 2. You can select the menu that you want to set. Enter number of set menu
by pressing the arrow keys and then press ENTER key.
6.2. Available keys
: Used to move the input value to the left or right by one place.
: Used to increase the setting constant one by one.
: Used to escape from setting mode.
: Used to move next menu after completing input value.
6.3. Function menu
General function
◊
F01: A/D output data rate (0~9)
Value
Description
00
256Hz
If a higher parameter is set, the display speed will be
slow, but response will be more insensitive to
environment such as vibration.
In contrast, If a lower parameter is set, the display
speed will be fast, but response will be more sensitive to
environment such as vibration.
01
128Hz
02
64Hz
03
32Hz
04
16Hz
05
10Hz
06
8Hz
07
6Hz
08
4Hz
09
2Hz
Bolded display is factory default set value.