DIGITAL WEIGHING INDICATOR TI-5700
- 38 -
8.2. Customer programmed control
Normal batching 1 (F21-4)
Relay OK output can be changed to Over/Under/Finish by setting F24.
HI, OK outputs operate in more than 5division.
◊
Relay output signal is as follows.
1. Press TARE key so that the display shows 0kg.
2. Final: It is ON when the net weight is greater than the weight (Final
– Free fall).
3. Over: It is ON when the net weight is greater than the weight (Final + High limit)
after Final output is ON and HI lamp turns on.
4. Under: It is OFF when the net weight is greater than the weight (Final
– Low limit)
after Final output is ON and LO lamp turns on.
5. Finish: When weight is stable, it is ON after passing the certain time of finish
start delay and OK lamp turns on. Finish signal is OFF when gross weight is
lower than 5 divisions.
6. Zero band: It is ON when gross weight is lower than zero band value.
◊
Status and display lamp
Display lamp
HI
OK
LO
Status
Over
Finish
Under