EF200R-C
53
Used in combination with flanges according to DIN EN 1092-1: PN 40
1.4404 (316, 316L)
DN
[mm]
Centering diameter
[mm]
D1
1)
/ D2
2)
s
[mm]
200
294.0
D2
26.3
250
355.0
D2
33.0
1)
The flow conditioner is fitted at the outer diameter between the bolts.
2)
The flow conditioner is fitted at the indentations between the bolts.
Used in combination with flanges according to ASME B16.5: Class 150
1.4404 (316, 316L)
DN
[mm]
Centering diameter
[mm]
D1
1)
/ D2
2)
s
[mm]
15
50.1
D1
2.0
25
69.2
D2
3.5
40
88.2
D2
5.3
50
106.6
D2
6.8
80
138.4
D1
10.1
100
176.5
D2
13.3
150
223.5
D1
20.0
200
274.0
D2
26.3
250
340.0
D1
33.0
1)
The flow conditioner is fitted at the outer diameter between the bolts.
2)
The flow conditioner is fitted at the indentations between the bolts.
Used in combination with flanges according to ASME B16.5: Class 300
1.4404 (316, 316L)
DN
[mm]
Centering diameter
[mm]
D1
1)
/ D2
2)
s
[mm]
15
56.5
D1
2.0
25
74.3
D1
3.5
40
97.7
D2
5.3
50
113.0
D1
6.8
80
151.3
D1
10.1
100
182.6
D1
13.3
150
252.0
D1
20.0
200
309.0
D1
26.3
250
363.0
D1
33.0
1)
The flow conditioner is fitted at the outer diameter between the bolts.
2)
The flow conditioner is fitted at the indentations between the bolts.