
EF200R-C
29
Influence of ambient
temperature
Current output
o.r. = of reading
Additional error, in relation to the span of 16 mA:
Temperature coefficient at
zero point (4 mA)
0.02%/10 K
Temperature coefficient
with span (20 mA)
0.05%/10 K
Pulse/frequency output
o.r. = of reading
Temperature coefficient
Max.
±
100 ppm o.r.
Installation
Mounting location
1)
2)
A0042128
1
Installation suitable for gases and steam
2
Installation not suitable for liquids