17
Power measurement reader
Yes
Power consumption readers
Yes
H1 and H2 overload detection
Yes
6.3.2
Orion
–
RS485 bus communication (kpBus)
Type of controller
connected:
Polyx, Pluto
Number
Connection
Digital input
2
T1, T2
Digital output
8
O1, O2, O3, O4, O5, O6, H1 and H2
Monitored inputs (ADC)
6
A1, A2, A3, A4, A5, A6
Orion override input
1
T
Wiegand/ABA card reader
2*
LD, D0, D1, C and V+
kpSensor
2**
C, S
Location buzzer
Yes
Status LED
Yes
MicroSD card
For emergency card use
RJ45
–
PRT2
kpBus communication
Indoor temperature sensor
Yes
Power supply measurement
Yes
Power measurement reader
Yes
Power consumption readers
Yes
H1 and H2 overload detection
Yes
6.3.3
Orion
–
functional replacement for the Orbit
reader
Type of controller connected:
iPU-8, Polyx or Pluto
Number Connection
Digital input
8
A1, A2, A3, A4, A5 A6, T1, T2
Digital output
4
H1, H2, O2, O5
Wiegand/ABA card reader
2
LD, D0, D1, C and V+
Status LED
Yes
RJ45
–
PRT1
RS422 communication with controller
Indoor temperature sensor
Internal only
Power supply measurement
Internal only
Power measurement reader
Internal only
Power consumption readers
Internal only
H1 and H2 overload detection
Internal only
* D0 and D1 are shared inputs. If no card reader is used, D0 and D1 can be used as digital
inputs.
** Only the combined Temperature & Humidity sensor supplied by Keyprocessor is supported.
Summary of Contents for KEYPROCESSOR Orion
Page 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Page 4: ...4 ...
Page 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Page 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Page 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Page 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Page 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Page 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Page 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Page 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Page 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...