22
Events
Nr. Description
1
Push button access
2
Push button no access
3
Card access
4
Card no access
5
Card no calamity card
6
Emergency door release activated
7
Emergency door release deactivated
The following table shows all the inputs:
Inputs
Nr. Connection:
Description:
Reader nr. Invert (NO/NC)
1
A1
Loop (enable)
Reader 1
Yes
2
A2
Push button
3
T1
Emegency door release
4
A4
Loop (enable)
Reader 2
5
A5
Push button
6
T2
Emegency door release
The following table shows all the outputs:
Outputs
Nr. Connection:
Description:
Reader nr.
Invert (NO/NC)
1
H1
Door lock
Reader 1
Yes
2
O1
Output
3
O2
Alarm
4
O3
Output
5
H2
Door lock
Reader 2
6
O4
Output
7
O5
Alarm
8
O6
Output
The following table shows the reader:
Reader
Nr.
Description:
Protocol:
Kaartdata
interpretation:
Pincode
function offline
1
Reader 1
Clock
–
data/ Wiegand
Max. 1
Pincode
switched off
2
Reader 2
Clock
–
data/ Wiegand
Max. 1
Note:
It is possible to use combined input or output by a reader. Consider a door with a card
reader on both sides.
Summary of Contents for KEYPROCESSOR Orion
Page 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Page 4: ...4 ...
Page 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Page 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Page 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Page 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Page 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Page 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Page 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Page 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Page 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...